OSTBERG LPK Series Installation And Directions For Use Download Page 2

2

This directions for use contains the following product: 

Low profile in line duct fan ’LPK’

Read and save these directions.

I N S T A L L A T I O N

D E S C R I P T I O N

•  The fan is used for transportation of ”clean” air,

meaning not intended for fire-dangerous substan-
ces, explosives, grinding dust, soot, etc.

•  The fan is equipped with an asynchronous external 

rotor induction motor with maintenance-free 
sealed ball-bearings.

•  To achieve maximum life length for installations in 

damp or cold environments, the fan should be ope-
rating continuously.

•  The fan can be installed outside or in damp envi-

ronments. Make sure that the fan-house is equip-
ped with drainage.

•  All ’LPK’-fans are as standard, single phase 110-127 

V 60 Hz.

•  The fan can be installed vertically or horizontally.

• The fan has rotating parts, therefore safety precau-

tions should be exercised during installation, opera-
tion and maintenance. Tighten all screws before 
operation unit.

USE HAND PROTECTION AND 

STAY CLEAR OF SHARP EDGES.

•  The fan must be installed according to all local and 

national codes and the air direction label on the 
fan.

•  The fan must be connected to duct or equipped 

with a safety grill.

•  The fan should be installed in a safe way not to 

cause vibrations or risking the fan to fall off.

•  A wiring diagram is applied on the inside of the 

junction box.

•  Use this unit only in the manner intended by the 

manufacturer. If you have any questions, contact 
your manufacturers representative.

•  Before servicing and cleaning unit, switch power 

off at service panel and lock the service disconnec-
ting means to prevent power from being switched 
on accidentally. When the service disconnecting 
means cannot be locked, securely fasten a promi-
nent device, such as a tag, to the service panel.

•  Installation work and electrical wiring must be 

done by qualified person(s) in accordance with all 

applicable codes and standards, including fire-rated 
construction.

• When cutting or drilling into the wall or ceiling, do 

not damage electrical wiring or other hidden utili-
ties.

• Ducted fans must always be ventilated to the out-

doors.

• Do not install this unit above a tub or a shower, if 

it’s not marked as appropriate for the application.

Never

place a switch where it can be reached from 

a tub or shower.

O P E R A T I O N

Before starting, make sure that:

•  the fan is installed and electrically connected in the 

correct way to ground.

•  the current does not exceed more than +5% of 

what is stated on the label.

•  No foreign object are placed in the fan and no 

noise appears when starting the fan.

CAUTION! FOR GENERAL VENTILATION USE ONLY. DO NOT USE TO EXHAUST HAZARDOUS 
OR EXPLOSIVE MATERIALS AND VAPORS.

WARNING! TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK OR INJURY TO PERSONS, 
OBSERVE THE FOLLOWING:

1270140_LPK_UL_utg1.qxp  2009-09-04  10:23  Sida 2

Summary of Contents for LPK Series

Page 1: ...UL VERSION Installation and directions for use Low profile duct fan LPK 1270140_LPK_UL_utg1 qxp 2009 09 04 10 23 Sida 1...

Page 2: ...the inside of the junction box Use this unit only in the manner intended by the manufacturer If you have any questions contact your manufacturers representative Before servicing and cleaning unit swit...

Page 3: ...ur manufacturers representative Before service and cleaning of the unit switch off the power at the service panel and lock the service disconnecting means to prevent power from being switched on accid...

Page 4: ...60 0 94 107 1500 3 8 4040076 8 F IP 44 LPK 6 B 115 60 1 33 143 1895 4 4 4040076 16 F IP 44 LPK 6 D 115 60 1 63 186 2155 4 6 4040076 16 F IP 44 W I R I N G D I A G R A M S Fanmotor Green White Black R...

Page 5: ...8K To environment 50 57 29 45 47 48 53 52 46 39 Inlet 71 56 64 67 64 58 56 58 56 Outlet 74 58 63 68 67 67 60 63 61 LPK 6 D 220 CFM 1 1 H2O LpA LwA tot dB A 63 125 250 500 1K 2K 4K 8K To environment 5...

Page 6: ...6 P R E S S U R E A N D F L O W D I A G R A M S LPK 4 A B LPK 5 A B LPK 6 B D 1270140_LPK_UL_utg1 qxp 2009 09 04 10 23 Sida 6...

Page 7: ...Exhaust system Exhaust system for ceiling Exhaust system The LPK fan can easily be mounted with the four brackets in any position Installation instructions for exhaust systems for duct fan type LPK 7...

Page 8: ...1270140UL 0906 Utg 1 OSTBERG AMERICAS INC 55 Raglin PL 3 Cambridge N1R 7J2 Canada Phone 519 623 6363 Telefax 519 623 8543 www ostberg com 1270140_LPK_UL_utg1 qxp 2009 09 04 10 23 Sida 8...

Reviews: