ProPoint Pixel

  

Mounting Guide

3a

3b

Data Wiring 
Overview

Termination Kit 
Overview

Data Wiring  
Intermediate Connections

Data Wiring
End Termination

3c

3d

WARNING:

 Risk of electrical shock. Make sure that the branch circuit is disconnected 

prior to installation or inspection.

CAUTION:

 Make sure that the cable is protected from cuts and abrasions that may result 

in damage to the outer jacket.

CAUTION:

 IP failure induced by stressed/damaged cable entry points during or after 

installation will void the product warranty.

NOTICE:

 A voltage divider is recommended (and may be required by local electrical code) 

when a single junction box is utilized for termination of the power supply and data cables.

NOTICE:

 Cable bend radius must NOT be less than the 

Minimum Bending Radius (4X Cable Diameter) as specified

 

by cable manufacturer and the Non-Bendable Length of 
5cm (2in) near the cable gland MUST be adhered to. In 
addition to the Minimum Bending Radius, ensure that 5cm 
(2in) of cable at the connector junction is kept straight (see 
image at right).

Note:

 Wire nuts are not permissible for use with data connections and will void warranty.

Terminating Resistor

For use in terminating the DMX512 data line at the last luminaire. See section 2.6 of the 
install guide for additional information on usage. 
Installed data cabling shall conform to the requirements outlined in ANSI E1.11 
Entertainment Technology – USITT DMX512-A, Asynchronous Serial Digital Data 
Transmission Standard for Controlling Lighting Equipment and Accessories. All cabling 
shall utilize stranded conductors. Solid core conductors shall not be used.
A maximum of 32 ProPoint luminaires may be connected to a DMX data line. The 
maximum overall data line length (from DMX controller to the last unit in the daisy chain) 
is 300m (984ft).

Termination Kit

A ProPoint termination kit (part number AM243520054) may be ordered separately. 
This kit contains the following components:
(6) Splicing wire connectors: For use in connecting data cable conductors. 
See section 2.6 of the install guide for additional information on usage. 

WARNING:

 Risk of electrical shock. Ensure that branch circuit power is disconnected 

prior to performing installation or inspection of data wiring.

NOTICE:

 A voltage divider is recommended (and may be required by local electrical 

code) when a single junction box is utilized for both power supply and data cable 
termination.

WARNING:

 Risk of electrical shock. Ensure that branch circuit power is disconnected 

prior to performing installation or inspection of data wiring.

NOTICE:

 A voltage divider is recommended (and may be required by local electrical 

code) when a single junction box is utilized for both power supply and data cable 
termination.

Note:

 

• Maintain data pair wire twist at all connection points.
• To prevent short circuits, do not strip more conductor insulation than required for

connection.

• The use of wire nuts is not acceptable and will void the warranty.
• Data termination shall be made in weatherproof enclosure by others. Use suitable

cable glands and apply RTV sealant at all entry points.

NOTICE:

 Termination is required for proper operation and shall be made at the last 

unit of the daisy chain only. Failure to install termination correctly will void the warranty.

Note:

 

• Maintain data pair wire twist at all connection points.
• To prevent short circuits, do not strip more conductor insulation than required for

connection.

• The use of wire nuts is not acceptable and will void the warranty.
• Data connections shall be made in weatherproof enclosure by others. Use suitable

cable glands and apply RTV sealant at all entry points.

NOTICE:

 DMX data must enter each fixtur

e using the DMX In wire pair (Black and 

Red conductors) and exit each fixtur

e using the DMX Out wire pair (Black and White 

conductors). Do not connect data wiring in a star or tap configuration. Doing so will

 

void the warranty and may result in control issues.

Minimum Bending Radius

DMX +

DMX -

COM

DMX +

DMX -

COM

To ProPoint luminaire

Data pair to luminaire

Data pair from luminaire

WAGO 221-412 Lever Nut 

(Typical of 6)

Data from previous luminaire or 
DMX data source

Data to next luminaire

DMX +

DMX -

COM

DMX +

DMX -

COM

Data from previous luminaire or 
DMX data source

WAGO 221-412 Lever Nut 

(Typical of 6)

To ProPoint luminaire

Data pair to luminaire

Data pair from luminaire

120 Ohm Terminator

www.traxontechnologies.com
www.osram.us/traxon

©2020 TRAXON TECHNOLOGIES – AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXON

 AND TX CONNECT

®

 ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. 

PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
Mounting Guide

 

7/20 V1