background image

 

Page 8  

 

Operating instructions: Mini Remote Control DALI RMC – M  ADVANCED 

 

 

6.  

Technical data 

 
Power supply: 

3 V DC 

 

Batteries: 

1x lithium button cell (CR 2032) 

 

Battery life: 

approx. 5 years 

 
Transmission frequency: 

433.42 MHz, ASK 

 
Range: 

max. 30 m (in the open) 

 
Dimensions (LxWxH): 

73 x 40 x 19 mm 

 
Temperature range: 

0 °C to +55 °C 

 
Rel. humidity: 

max. 80 % 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 

 
 

D

igital 

A

ddressable 

L

ighting 

I

nterface 

 
The international digital interface standard for the lighting industry 

 
 
 
 
 
 

Date 13.09.02 / Remote Control ADVANCED Mini Version 1.0 

 
 
 

Subject to change without notice. Errors and omission excepted. 

Summary of Contents for DALI RMC ADVANCED

Page 1: ...ol Type DALI RMC ADVANCED OSRAM GmbH Hellabrunner Str 1 D 81536 Munich Tel 49 0 89 6213 0 Fax 49 0 89 6213 2020 Customer Service Center KSC Germany Albert Schweitzer Str 64 D 81735 Munich Tel 49 0 180...

Page 2: ...Page 2 Operating instructions Mini Remote Control DALI RMC M ADVANCED...

Page 3: ...Control DALI RMC M ADVANCED Page 3 Contents 1 Function overview Page 4 2 Programming in the DALI ADVANCED central unit Page 4 3 Operation Page 5 4 Changing the battery Page 5 5 Notes on radio operati...

Page 4: ...s that have been programmed for them 2 Programming in the DALI ADVANCED central unit Before the central unit can understand a radio telegram from the hand held transmitter it must learn it The learnin...

Page 5: ...tem up holding down will fade it down When operating the louvre blind actuator a short press will change the angle of the louvres whereas a long press will raise or lower the blinds Note The maximum d...

Page 6: ...er by undoing the screw Fig B 2 Remove the old battery from the battery compartment 3 Insert the new battery Make sure it is the right way round on top see Fig C 4 Replace the cover and tighten the sc...

Page 7: ...e range of the hand held transmitter up to 30 m in the open depends on the nature of the building Dry material Penetration Wood plaster plasterboard approx 90 Brick MDF approx 70 Reinforced concrete a...

Page 8: ...Transmission frequency 433 42 MHz ASK Range max 30 m in the open Dimensions LxWxH 73 x 40 x 19 mm Temperature range 0 C to 55 C Rel humidity max 80 Digital Addressable Lighting Interface The internat...