background image

2

XTYLOS

1.  SAFETY INFORMATION

* see at page 12 for other languages
Please  read  this  document  carefully  and  keep  it  for  future  reference.  CLAY  PAKY  S.p.A.  disclaims  any  liability  for
damage to the appliance or property or injury to third parties resulting from installation, use or service that is not carried
out in accordance with the instructions in this document and in the instruction manual. The instruction manual may be
downloaded from the website www.claypaky.com and must be kept with the appliance. CLAY PAKY S.p.A. reserves the
right to modify the instructions and specifications shown in its documentation at any time without notice.

• Installation

Make sure all parts for fixing the luminaire are in a good state of repair. Make sure the point of anchorage is stable
before  positioning  the  luminaire.  The  safety  chain  must  be  properly  hooked  onto  the  fitting  and  secured  to  the
framework, so that, if the primary support system fails, the fitting falls as little as possible. If the safety chain gets
used, it needs to be replaced with a genuine spare.

• Photobiological safety

This product includes a light source based on laser diodes. It complies with the requirements of clause 4.4 of the
laser safety standard IEC 60825-1:2014 (3rd edition), hence:
• It is a “laser product designed to function as conventional luminaire” as defined in the clause 4.4 itself, so it is

classified as CLASS 1 LASER PRODUCT according to IEC 60825-1:2014.

• Photobiological  risk  classification  is  performed  according  to  the  standard  IEC  62471:2006,  for  conventional

luminaires, using 2013 ICNIRP exposure limits, resulting in a Risk Group 3 (RG3).

Class 1 Laser product (IEC 60825-1:2014) - RG3 (IEC 62471:2006)

• Possibly hazardous optical radiation emitted from this product.
• Do not look at operating lamp source, closer than the Hazard Distance. Eye injury may result.
• Caution - Use of controls or adjustments or performance of procedures other than those specified  herein may

result in hazardous light exposure.

• The US Food and Drug Administration (FDA) requires this product to be purchased and operated in the US under

the  terms  of  a  permit.  This  permit  which  is  issued  by  the  FDA  at  no  cost  is  called  a  variance.  See  variance
document for required procedures.

• All  operators  must  be  a  legal  employee  of  the  variance  holder  and  have  completed  a  simple  training  course

including safety and operation. 

• Operators shall control access to the beam within the hazard distance or install the product at the height that will

prevent spectators’ eyes from being within the hazard distance.

• The luminaire is in excess of the Exempt Risk Group; the viewer-related risk is dependent upon how the user

install and use the product. 

Hazard distances (depending on settings):

see operating procedure for more information
This Laser Product is designated as Class 1 / RG3 during all procedures of operation.
• Do not operate with personnel exposure shorter than the declared hazard distance due to risk of skin or corneal burns.
• The unit is never to be operated if defective or the covers or seals are damaged.
• No maintenance is required by the user.
• The  user  must  not  modify  the  unit  or  remove  protective  covers  or  housings  except  for  service:  potentially

hazardous Class 3B Laser light is accessible if service procedures are not followed.

• Service is only to be performed by trained and authorized personnel. Refer to Service Manual for detailed safety information.

HD = 82ft. 25.0 m.
HD = 70ft. 21.5 m. 
HD = 60ft. 18.5 m.  
HD = 50ft. 15.0 m. 
HD = 26ft. 08.0 m.

Summary of Contents for CJ3000

Page 1: ...RGB additive color mixing In contrast to the subtractive mixing used with discharge lamps colored light beams are as bright as a white light beam The range of effects features two gobo wheels with 7 rotating gobos and 12 fixed gobos including 7 beam diameter reducers a wheel with 3 prisms and a sixteen facet prism on a dedicated channel which can be overlapped with the prism wheel The Xtylos is de...

Page 2: ...uct IEC 60825 1 2014 RG3 IEC 62471 2006 Possibly hazardous optical radiation emitted from this product Do not look at operating lamp source closer than the Hazard Distance Eye injury may result Caution Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous light exposure The US Food and Drug Administration FDA requires this product to ...

Page 3: ...maximum temperature that can be reached on the external surface of the fitting in a thermally steady state is 60 C 140 F IP20 protection rating The fitting is protected against penetration by solid bodies of over 12mm 0 47 in diameter first digit 2 but not against dripping water rain splashes or jets of water second digit 0 Minimum distance of illuminated objects The luminaire needs to be position...

Page 4: ...4 XTYLOS 2 UNPACKING AND PREPARATION CLAY PAKY S p A AN OSRAM BUSINESS Via Pastrengo 3 b 24068 Seriate BG Italy Tel 39 035 654311 info claypaky it www claypaky it 1 Labeling information Fig 1 ...

Page 5: ...5 XTYLOS Labeling information Fig 2 2 ...

Page 6: ...6 XTYLOS 3 PAN Mechanism Lock and Release every 90 Fig 4 TILT Mechanism Lock and Release every 45 Fig 5 Packing contents Fig 3 90 9 0 9 0 9 0 UNLOCKED LOCKED 4 5 4 5 45 4 5 45 2 x 183102 805 4 5 ...

Page 7: ...irection of the fixture is not occurring WARNING with the exception of when the luminaire is positioned on the floor the safety cable must be fitted Cod 105041 001 available on request This must be securely fixed to the support structure of the luminaire and then connected to the fixing point at the centre of the base 3 1 Installing the fixture 3 2 Connecting to mains supply WARNING Operators shal...

Page 8: ...ay automatically returns to rest status It should be noted than when this condition occurs any possible value that has been modified but not yet confirmed with the Fkey will be cancelled 1 2 Dmx Address Warning Message Fixture ID 10 Connecting to the control signal line DMX Fig 9 Use a cable conforming to specifications EIA RS 485 2 pole twisted shielded 120Ohm characteristic impedance 22 24 AWG l...

Page 9: ...settings Once the required operations have been carried out the display will switch off again after a wait time of 30 seconds see DMX Channels and User Menu chart to set the correct fixture configuration USING THE MENU 1 Press F once Main Menu appears on the display 2 Use the UP B and DOWN C keys to select the menu to be used Setup Setup Menu To set the setting options Option Option Menu To set th...

Page 10: ...nd logging Cooling system monitoring DMX level monitoring on all channels Internal data transmission diagnostics Upgrade with no power CPU only firmware Firmware upload from another fixture CPU only Firmware Upgrade via Web Server Protocols Functions RDM Web Server ArtNet Extremely reliable communication RS485 bus INPUTS DMX 512 5 pin In Out connector Ethernet Neutrik PowerCon True1 IN OUT IP RATI...

Page 11: ...11 XTYLOS ...

Page 12: ...i controlli o adattatori o l esecuzione di procedure diverse da quelle specificate nel presente documento possono comportare un esposizione alla luce pericolosa La Food and Drug Administration FDA statunitense richiede che questo prodotto venga acquistato e utilizzato negli Stati Uniti secondo i termini di un permesso Tale permesso erogato gratuitamente dalla FDA viene detto variance Controllare i...

Page 13: ...a massima temperatura raggiungibile sulla superficie esterna del proiettore in condizioni termiche stabili è di 60 C 140 F Grado di protezione IP20 Il proiettore è protetto dalle infiltrazioni di corpi solidi superiori ai 12mm 0 47 di diametro prima cifra 2 ma non da quelle di gocce d acqua pioggia schizzi o getti d acqua seconda cifra 0 Distanza minima dagli oggetti illuminati Il proiettore deve ...

Page 14: ...rwendung von Steuerungen oder Einstellungen sowie die Durchführung anderer als der hier angegebenen Verfahren kann zu einer gefährlichen Lichtexposition führen Die US amerikanische Food and Drug Administration FDA schreibt vor dass dieses Produkt in den USA nur mit einer Genehmigung gekauft und betrieben werden darf Diese von der FDA kostenlos erteilte Genehmigung wird als Abweichung bezeichnet Di...

Page 15: ...ie maximale Temperatur die dauerhaft an der Außenfläche des Anschlussstücks erreicht werden darf beträgt 60 C 140 F Schutzart IP20 Die Armatur ist gegen das Eindringen von festen Körpern mit einem Durchmesser von mehr als 12mm 0 47 geschützt erste Ziffer 2 jedoch nicht gegen tropfendes Wasser Regen Spritzer oder Wasserstrahlen zweite Ziffer 0 Mindestabstand von beleuchteten Objekten Die Leuchte mu...

Page 16: ...uí indicados podrían provocar una exposición peligrosa a la luz La Administración de Alimentos y Medicamentos FDA de los Estados Unidos exige que este producto se compre y se emplee en los Estados Unidos en los términos de un permiso Este permiso emitido por la FDA de forma gratuita se denomina variance variación Consulte el documento variance para conocer los procedimientos requeridos Todos los o...

Page 17: ... alcanzar la superficie externa del aparato en condiciones térmicas estables es de 60 C 140 F Grado de protección IP20 El aparato está protegido contra la penetración de cuerpos sólidos con un diámetro superior a 12 mm 0 47 primer dígito 2 pero no contra el goteo de agua la lluvia las salpicaduras y los chorros de agua segundo dígito 0 Distancia mínima de los objetos iluminados La luminaria debe c...

Page 18: ...stements ou l exécution de procédures autres que celles spécifiées dans le présent document peuvent entraîner une exposition dangereuse à la lumière La Food and Drug Administration FDA Agence américaine des produits alimentaires et médicamenteux exige que ce produit soit acheté et exploité aux États Unis selon les termes d un permis Ce permis qui est délivré gratuitement par la FDA est appelé vari...

Page 19: ... maximale pouvant être atteinte sur la surface extérieure du raccord en régime de stabilité thermique est de 60 C 140 F IP20 indice de protection L appareil est protégé contre la pénétration de corps solides de plus de 12 mm de diamètre premier chiffre 2 mais pas contre les gouttes d eau la pluie les éclaboussures ou les jets d eau deuxième chiffre 0 Distance minimale des objets éclairés Le lumina...

Page 20: ...вления регулировки или выполнение действий отличных от указанных в данном документе может привести к опасному воздействию света высокой интенсивности В соответствии с требованиями Управления по контролю за продуктами питания и лекарственными средствами США FDA на приобретение и эксплуатацию данного изделия на территории США требуется специальное разрешение Данное разрешение FDA выдает бесплатно По...

Page 21: ...пература на наружной поверхности прибора в термически устойчивом состоянии составляет 60 C 140 F Степень защиты IP20 Корпус прибора защищает от проникновения внутрь предметов с диаметром более 12 мм 0 47 дюйма первая цифра 2 но не защищает от попадания капель воды дождя брызг или струй воды вторая цифра 0 Минимальное расстояние от освещаемых предметов Светильник должен быть расположен таким образо...

Page 22: ...22 XTYLOS ...

Page 23: ...23 XTYLOS ...

Page 24: ...IST01L 001 EN PRELIMINARY 04 2020 CLAYPAKY S p A Via Pastrengo 3 b 24068 Seriate BG Italy Tel 39 035 654311 www claypaky com ...

Reviews: