The company reserve the right to alter size, shape and specification without prior notice
Page 22
6.1. Domestic hot water advanced menu (control panel type 2)
Display of desired secondary (DHW) temperature
Press the key (8)
up
and release, LED display will show desired secondary
(DHW) temperature. The value is shown for 5 s, after which display reverts to
actual temperature of primary water in the boiler.
Setting desired secondary (DHW) temperature
Press key (8)
up
and hold for more than 5 seconds to set secondary (DHW)
temperature.
The desired secondary (DHW) temperature blinks.
By pressing the key (8) up or down the value of desired secondary (DHW)
temperature in the storage cylinder changes in 1°C steps. If there is no pressure
on the key for more than 5s the value from the display is saved as the desired
secondary (DHW) temperature.
Possible adjustment from 10°C up to 65°C.
Factory default is 50°C.
Displaying software version and factory reset
>5 sec
50
50
>5 sec
>10 sec
32
>5 sec
<5 sec
1.4
Press key (8)
up
and hold for longer than 15 sec, LED will show software version
and factory reset of central heating parameters will occur.