TERMINOLOGY USED IN THIS MANUAL 

The central heating boiler water circuit is called primary  

1. Introduction 

Thank you for purchasing the Oso Termo E electric central heating boiler. 
To ensure a correct and safe installation and economical use, please read these instructions thoroughly before 
installation. 

1.1. Applicable documents 

The following additional documents are provided with the appliance: 
 

For the owner of the system: 

Instructions for use 
Warranty card 

For the qualified technician: 

Instructions for installation 
Electrical drawing for the appliance 

1.2. Retention of documents 

Please pass on this installation manual to the owner of the system. The owner should retain the manuals so that 
they are available when required. 

1.3 Termo - E concept 

The Termo Plus E is a wet system electrically heated boiler for space heating only. It is not suitable for use with 
an indirect water heater and should not be used under any circumstances to heat domestic hot water. 
The boiler provides wet system central heating by passing the primary water over the immersion heaters. The 
immersion heaters are located on the under-side of boiler ensuring the elements are constantly immersed in the 
heating medium (water with appropriate inhibitor).  
Termo Plus E uses weather compensation/heat curve technology. An outside sensor supplied with the boiler 
informs the boiler of the outside temperature. This information is used by the boiler to set a temperature in the 
heating system. The colder the external temperature, the more internal heating is required. 
The boiler is supplied with a range of heat curves built into its software. Once correctly set, the heat curve need 
never be altered. Heat curves are set according to the insulation levels of the property. A poorly insulated house 
will require a higher primary heating temperature. 
Selecting the heating curves at the time of installation is a simple process for the installer. A table is shown on 
page 13 indicating which heating curve is required for the building type. Once the heating curve is correctly set, it 
should never require changing. 
The heating curve will aim for the property to be heated to 22°C. Not all households wish for the same internal 
temperature, if the residents of the property require a higher or lower temperature, the selected curve should be 
offset up or down by the appropriate number of degrees. Full instructions are given on page 14. 
A room thermostat (not supplied) must be installed to finely regulate internal temperatures.  
Heat curve systems operate for longer periods at lower temperatures than traditional systems and can typically 
make savings of up to 15% over a standard heating system. Heat curve systems are widely used in Europe but 
relatively new in the UK. 
Heating curves also vary according to radiator or under-floor heating.  The factory set heating curve is for a 
building constructed to 2000 building regulations with radiator heating. Many boilers therefore will not require 
adjustment of heating curve. 
 
The boiler will modulate 1, 2 or 3 elements to achieve the desired primary temperature. The boiler reservoir is 
insulated with 19 mm self-extinguishing Armaflex insulating material, which is sufficient to direct the whole heat 
only to the heating system.  
The boiler operates by rapidly heating a small water quantity. Energy use is maintained at 100% efficiency. 
No flue or fan required - Almost silent in operation - No bulk oil storage tanks required 
No annual safety check required  
 
 

 
 

Summary of Contents for OSO TERMO PLUS-E

Page 1: ...The company reserve the right to alter size shape and specification without prior notice TMS UT 0804 Z01 4 page 1 TERMO ELECTRIC BOILER INSTALLATION MANUAL OSO TERMO PLUS E...

Page 2: ...4 6 CONNECTION PLATE FOR CONTROL EQUIPMENT TEMPERATURE SENSOR PUMP 10 4 6 1 CONNECT ROOM THERMOSTAT PROGRAMMER 10 4 6 2 FIT EXTERNAL TEMPERATURE SENSOR 10 5 SETTING UP BOILERS 11 5 1 CONTROL PANEL INC...

Page 3: ...nge of heat curves built into its software Once correctly set the heat curve need never be altered Heat curves are set according to the insulation levels of the property A poorly insulated house will...

Page 4: ...ow 2 Primary return 3 External boiler jacket 4 Boiler 5 Armaflex insulation 6 Electrical heaters 7 Control panel 8 Cable entry point 9 Contactors 10 Expansion vessel 11 Circulation pump 12 Safety valv...

Page 5: ...A 330 B 930 C 230 D 100 E 65 F 320 34 5 0 25 2 5 240V N 50 60 Hz 2 2 Expansion Vessel Characteristics Volume of Expansion Vessel L Maximum Expansion Vessel Pressure MPa bar Pre charge Pressure MPa ba...

Page 6: ...ts that may considered hazardous to health and safety Control of Substances Hazardous to Health COSHH 1988 Glues paints and sealants are used in the manufacture of this product and present no known ha...

Page 7: ...see page 12 No 3 to the wall using suitable plastic plugs and M8 or M10 screws not supplied Decide the position of the bottom of the boiler giving due consideration to the recommended minimum clearan...

Page 8: ...ncillary components If the capacity of the in built expansion vessel on Plus E is not sufficient for the heating system indicated by pressure increase of 0 6bar when system is heated an additional exp...

Page 9: ...ol equipment programmer timer thermostats etc MUST be supplied with power from the boiler connections plate see section 4 6 DO NOT supply with power directly from the mains supply In order to connect...

Page 10: ...vice room thermostat and or programmer is used remove this link Switched live from room thermostat and water heater thermostat must be connected to 4 CH ON 4 6 2 Fit external temperature sensor The ex...

Page 11: ...many heating elements are active 3 Led diode OK air in boiler If there is no air in the boiler the diode lights green If air appears in the boiler the diode lights red and the boiler shuts down Upon d...

Page 12: ...ontrol panel Re fit panel protector Re fit the boiler front cover 1 4 2 3 ON OFF Function Pin 1 ON Set heating type to under floor curves from 0 1 to 0 9 are active minimum boiler temperature is set t...

Page 13: ...oss control units With central heating programmer Honeywell ST6400 Danfoss TP 9 7 day programmer or similar it is possible to program separate periods of central heating from periods for domestic wate...

Page 14: ...f 0 1 see the diagram on the front plate If there is no pressure on the key for more than 5 seconds the curve displayed is saved Construction date Radiator curve under floor curve Pre 1970 2 0 0 9 197...

Page 15: ...t lower temperatures when required When setting variable temperatures please be aware that the heating system will take some time to heat up from cold and similarly will remain hot for some time after...

Page 16: ...re than 5 seconds the curve displayed is saved Limiting maximum power of boiler manually deactivating 1 or more immersion elements Press key 6 up and hold for 10 seconds to limit power level By pressi...

Page 17: ...ory setting is 0 C Offset range is from 9 to 20 C If there is no pressure on the key for more than 5s shown value of offset in C is saved Setting the minimum primary temperature inside boiler Press ke...

Page 18: ...heater switch relay is faulty Does DISPLAY show temperature inside boiler NO NO YES Is the temperature of water same as desired YES Wait for boiler to heat up NO Is the room thermostat switched ON YES...

Page 19: ...ow YES YES Is the operating thermostat defective NO NO Replace the operating thermostat with new YES Please check the following before going through fault finding flowchart Check the installation is c...

Page 20: ...mmersion heaters change the heaters YES Please check the following before going through fault finding chart Check the installation is correct All isolating valves are open The system is full of water...

Page 21: ...ater UK Ltd E15 Marquis Court Team Valley Tarding Estate Gateshead Tyne Wear NE11 0RU Tel 0191 482 0800 Fax 0191 491 3655 www oso hotwater com technical uk oso hotwater com sales uk oso hotwater com s...

Page 22: ...size shape and specification without prior notice TMS UT 0804 Z01 4 page 22 BASIC USAGE SAMPLE FOR CENTRAL HEATING With Termo Plus E electric boiler up to 14 4kw N 50 60Hz and up to 36 kw 415V 3 N 50...