Technical data - Delta Coil VIP

Technical DATA:  DELTA COIL VIP

Description

Unit

DC120

DC150

DC180

DC 200

DC250

DC300

Actual capacity of the water tank at 20°C

l

115

145

175

194

245

284

Outer diameter of the tank

mm

595

595

595

595

595

595

Height of the appliance

mm

845

1005

1170

1270

1540

1750

Gross weight of the appliance

kg

35

39,9

41,7

44,3

51,8

58

Net weight of the appliance

kg

32,7

36,9

38,1

40,7

48,1

53,2

Net weight of the appliance once filled with sanitary water

kg

148

186,1

214

239,7

297,9

342,5

Material of the tank / integrated heat exchanger

 -

1.4521 / 1.4521 1.4521 / 1.4521 1.4521 / 1.4521 1.4521 / 1.4521 1.4521 / 1.4521 1.4521 / 1.4521

Material of element

 -

incoloy 825

incoloy 825

incoloy 825

incoloy 825

incoloy 825

incoloy 825

Thermal insulation material

-

PUR

PUR+VIP

PUR+VIP

PUR+VIP

PUR+VIP

PUR+VIP

Thermal insulation of the tank, average thickness

mm

50

50

50

50

50

50

IP classification

-

21

21

21

21

21

21

Standby heat losses /24hour

kWh/24h

0,84

0,94

0,98

1,03

1,1

1,18

Standby heat losses 

Watts

35

39

41

43

46

49

Hot water capacity - mixed to 40°C

l

191

246

290

306

412

468

Heating time (upper Coil)

min

20,4

24,3

29,6

31,6

43,3

48,5

Reheat time (70%) (upper Coil)

min

15,3

18,2

22,2

23,7

32,5

37,1

Primary Heating Power (upper Coil)

kW

15,8

17,2

17,1

16,9

16,6

16,5

Primary flowrate for Reheat time and Primary heating 

l/h

900

900

900

900

900

900

Primary Heat exchanger pressure drop

mbar

50

50

50

50

50

50

ERP class

-

A

A

A

A

A

A

Pressure information

Maximum design pressure of cylinder (rated pressure)

MPa / 

1 / 10

1 / 10

1 / 10

1 / 10

1 / 10

1 / 10

Max. design pressure of heating coil

MPa / 

1 / 10

1 / 10

1 / 10

1 / 10

1 / 10

1 / 10

Max. design pressure of solar coil

MPa / 

N/A

N/A

N/A

N/A

N/A

N/A

operating pressure of cylinder

MPa / 

3

3

3

3

3

3

operating pressure of heating coil

MPa / 

2,5

2,5

2,5

2,5

2,5

2,5

operating pressure of solar coil

MPa / 

N/A

N/A

N/A

N/A

N/A

N/A

Max. operating temperature of cylinder

°C

70

70

70

70

70

70

Max. operating temperature on the heating coil

°C

99

99

99

99

99

99

Max. operating temperature on the solar heating coil

°C

99

99

99

99

99

99

Expansion solution

 -

Aquasystem 3 Bar Aquasystem 3 Bar Aquasystem 3 Bar Aquasystem 3 Bar Aquasystem 3 Bar Aquasystem 3 Bar

Expansion Vessel capacity

L

12

12

18

18

24

24

Exchanger information

Primary Heat exchanger volume

l

3,8

4,4

4,4

4,4

4,4

4,4

Primary Heat exchanger surface area

0,69

0,8

0,8

0,8

0,8

0,8

Ø Int. et Ø Ext.

mm/mm

ø20,4/ø22

ø20,4/ø22

ø20,4/ø22

ø20,4/ø22

ø20,4/ø22

ø20,4/ø22

Hydraulic connections

Secondary return

mm

N/A

N/A

N/A

N/A

N/A

N/A

Primary heat exchanger flow

inch

3/4"

3/4"

3/4"

3/4"

3/4"

3/4"

Primary heat exchanger return

inch

3/4"

3/4"

3/4"

3/4"

3/4"

3/4"

Cold water 

inch

3/4"

3/4"

3/4"

3/4"

3/4"

3/4"

Hot water 

inch

3/4"

3/4"

3/4"

3/4"

3/4"

3/4"

Immersion heater

inch

5/4"

5/4"

5/4"

5/4"

5/4"

5/4"

Expansion Relief Valve

inch

1/2

1/2

1/2

1/2

1/2

1/2

T & P Valve (Factory fitted)

inch

1/2

1/2

1/2

1/2

1/2

1/2

Pressure reducing Valve

inch

3/4

3/4

3/4

3/4

3/4

3/4

Temperature sensor sleeve diameter

mm

8

8

8

8

8

8

Electrical characteristics

Supply voltage and frequency

V/Hz

220-240 VAC

220-240 VAC

220-240 VAC

220-240 VAC

220-240 VAC

220-240 VAC

Power of the electrical resistance

-

3kW@240V

2,8kW@230V

electrical installation

 -

IEEE regs

IEEE regs

IEEE regs

IEEE regs

IEEE regs

IEEE regs

Thermostat type - immersion/cylinder

 -

Probe/Probe

Probe/Probe

Probe/Probe

Probe/Probe

Probe/Probe

Probe/Probe

Immersion Heater Phase

Phase

single

single

single

single

single

single

immersion thermostat - temp range

°C

18-70

18-70

18-70

18-70

18-70

18-70

immersion thermostat - set temp

°C

60

60

60

60

60

60

Indirect thermostat -  temp range

°C

25-65

25-65

25-65

25-65

25-65

25-65

Indirect thermostat - set temp

°C

60

60

60

60

60

60

Safety

safety valve opening pr/- 5%

Bar

6

6

6

6

6

6

T & P Valve opening pressure/Temp

Bar/°C

10/90

10/90

10/90

10/90

10/90

10/90

safety thermostat cutout -  immersion

°C

87

87

87

87

87

87

safety thermostat cutout -  cylinder

°C

80

80

80

80

80

80

Packaging

Width of Box

mm

610

610

610

610

610

610

Depth of Box

mm

610

610

610

610

610

610

Height of Box

mm

890

1070

1200

1320

1570

1780

Weight of Box

mm

40

45

47

49

57

63

3kW@240V

2,8kW@230V

3kW@240V

2,8kW@230V

3kW@240V

2,8kW@230V

3kW@240V

2,8kW@230V

3kW@240V

2,8kW@230V

Summary of Contents for Delta Coil DC 300

Page 1: ...r AS Industriveien 1 3300 Hokksund Norway Tel 47 32 25 00 00 Fax 47 32 25 00 90 E mail oso oso no www osohotwater com Delta Coil DC VIP 120 150 180 210 250 300 l UK SAFETY INFORMATION O M INFORMATION...

Page 2: ...ywhere open to frost attack The unit should be placed on a stable flat surface capable of withstanding the weight of the cylinder when full see technical data on page 10 and access must be allowed for...

Page 3: ...see Table 2 11 Hot Water Outlet 3 4 BSP 12 Elbow Drain Cock 250445 13 Discharge Pipe Not supplied 14 Motorised Valve Not factory fitted 92000 15 Expansion Vessel AX12 18 or 24 Size Length of tube 22...

Page 4: ...see 3 1 5 above to include a Tee piece if a secondary return is required 3 1 7 Fit the Multibloc 3 to the top of the copper tube see 3 1 6 above 3 1 8 Connect 15mm copper tube from the expansion reli...

Page 5: ...e unit will drain Draining process may be speeded up by opening the temperature and pressure relief valve An internal 18 mm hose can be applied to lead the water to a gully sink or similar 5 2 System...

Page 6: ...tch with a minimum 3 mm separation required All electrical wiring should be carried out by a competent electrician using a heat resistant cable minimum 85 C and be in accordance with the latest I E E...

Page 7: ...valve which will act as a positive energy cut out should the safety cut out operate The motorised valve will also control the temperature of the domestic stored water via the cylinder thermostat which...

Page 8: ...Pocket is provided see below to se cure the sensor on the Delta Coil cylin der The probe is run through a channel from base of cylinder to the immersion housing The supplied motorised valve must be us...

Page 9: ...rge from the tundish occurs when water is being heated In this situation maintenance must be car ried out by competent person and the precharge pressure must be restored to the original value An annua...

Page 10: ...ed on 1 Check and switch on 2 Immersion heater thermal cut out has operated 2 Check and reset button see thermostat diagram page 8 and safety cut out on page 5 of installation manual 3 Programmer set...

Page 11: ...Max operating temperature on the solar heating coil C 99 99 99 99 99 99 Expansion solution Aquasystem 3 Bar Aquasystem 3 Bar Aquasystem 3 Bar Aquasystem 3 Bar Aquasystem 3 Bar Aquasystem 3 Bar Expansi...

Page 12: ...12 All replacement parts should be supplied by OSO HOTWATER UK LIMITED For spare parts visit www oso spares co uk www oso hotwater com Delta Product Fiche...

Page 13: ...Regulations 3 Failure to install and commission this appliance to the manufacturer s instructions may invalidate the guarantee The above does not affect your statutory rights For full details on the H...

Page 14: ...rdance with European Council Directive 98 83 EC or revised version at the date of installation and is not fed with water from a private supply Particular Chloride content Max 250 mg l Sulphate content...

Page 15: ...HARGE TESTED IS PRIMARY ENERGY SOURCE CUT OUT FITTED NORMALLY 2 PORT VALVE WHAT IS THE PRESSURE REDUCING VALVE SETTING IF FITTED WHERE IS OPERATING PRESSURE REDUCING VALVE SITUATED NO YES NO YES NO ba...

Page 16: ...ENTS SIGNATURE DATE ENGINEER NAME SERVICE 5 COMPANY NAME TEL No COMMENTS SIGNATURE DATE ENGINEER NAME SERVICE 7 COMPANY NAME TEL No COMMENTS SIGNATURE DATE ENGINEER NAME SERVICE 9 COMPANY NAME TEL No...

Reviews: