13
!
WARNING
Constant voltage present in the junction box. Be-
fore any electrical work is done, the power supply
must be disconnected and secured against acti-
vation while the work is in progress.
5.1 Settings
5.1.1 Thermostat setting
The thermostat on the product is adjustable from
5-70°C. The thermostat should not be set lower
than 65°C to prevent bacteria growth. To adjust
the temperature:
A) Disconnect the power supply.
B) Remove the cover (1) with a screwdriver.
C) Adjust the temperature on the thermostat ad-
justment dial (2).
D)
The thermostat is adjustable from 5-70°C.
Turning the dial (2) all the way to +
gives the highest temperature (70°C).
The temperature can be reduced as desired by
turning the dial (2) towards (-).
Fit the cover (1) before connecting the power sup-
ply.
5.1.2 Resetting the safety thermostat
The safety thermostat on the product cuts out
when there is a risk of overheating. This is reset by
removing the cover (1) and pressing the ‘Safety’
button (3). If the thermostat cuts out repeatedly,
contact the installer.
5.1.4 Adjusting the feet
The product is equipped with three factory-
fitted feet, adjustable from 0-40 mm. Screw the
feet out a minimum of 15 mm from the bottom
of the product. Adjust the feet individually un-
til the product is standing firmly vertically and
horizontally.
5. USER GUIDE
R
S
-
+
P
a
te
nt
ed
T115
16
A
2
50
V
A
B
Safety
Type: TSR
COTHERM
-
+
P
a
te
nt
ed
T115
16
A
2
50
V
A
B
Safety
Type: TSR
COTHERM
R
S
2
3
Summary of Contents for Delta Coil DC 200
Page 16: ......