2.4  Technical data

Directive: 2010/30/EU  Regulation: EU 812/2013 

Directive: 2009/125/EC  Regulation: EU 814/2013

Heat loss tested acc. to standard: EN 12897: 2015

2. PRODUCT DESCRIPTION

2.1  Product identification

Identification details for your product can be found 
on the type plate fixed to the product. The type 
plate contains details of the product in accordance 
with EN 12897:2016 and EN 60335-2-21, as well as 
other useful data. See Declaration of Conformity at 
www.osohotwater.com for more information.

OSO products are designed and manufactured in 
accordance with:

•  Pressure vessel standard  EN 12897:2016
•  Safety standard  

EN 60335-2-21

•  Welding standard   

EN ISO 3834-2

OSO Hotwater AS is certified for 

•  Quality 

ISO 9001

•  Environment 

ISO 14001

•  Work environment 

OHSAS 18001

2.2  Intended use

The Maxi is designed for use as a buffer tank for 
heat-pumps/solar collectors, or as a cooler tank in 
cooling systems etc. 

 2.3  CE  marking

The CE mark shows that the product complies 
with the relevant Directives. See Declaration of 
Conformity at www.osohotwater.com for more 
information.

The product complies with EU Directives for:

• Low voltage 

LVD 2014/35/EU

• Electromagnetic compatibility  EMC2014/30/EU
• Pressurised equipment 

PED 2014/68/EU

The safety valve(s) used must be CE marked and 
conform to PED 2014/68/EU.

NRF no.  Product code: 

Capacity, 

persons

Weight, 

kg.

Diameter x height 

(mm)

Freight 

vol. m³

Heating time, 

hours 

D

t 65°C

Actual 

vol. l.

800 1353 MA 600 Heat

-

148

ø  780x1900

1,28

-

550

800 1354 MA 1000 Heat

-

238

ø1000x2100

2,29

-

885

800 1356 MA 2000 Heat

-

362

ø1300x2440

4,25

-

-

800 1357 MA 3000 Heat

-

566

ø1500x2695

6,25

-

-

800 1358 MA 5000 Heat

-

930

ø1700x3180

9,45

-

-

800 1363 MA 10000 Heat

-

1770

ø2000x4400

17,95

-

-

800 1253 MA 600 Cool

-

148

ø  780x1900

1,28

-

550

800 1254 MA 1000 Cool

-

238

ø1000x2100

2,29

-

885

800 1256 MA 2000 Cool

-

362

ø1300x2440

4,25

-

-

800 1257 MA 3000 Cool

-

566

ø1500x2695

6,25

-

-

800 1258 MA 5000 Cool

-

930

ø1700x3180

9,45

-

-

800 1263 MA 10000 Cool

-

1770

ø2000x4400

17,95

-

-

 2.5 ErP data - Technical Data Sheet

Brand

Model-no.

Model name

ErP 

profile

ErP 

rating  AEC - kWh/a

Thermostat 

setting °C

Volume 

40°C water

Heat 

loss W

OSO Hotwater AS

800 1353 MA 600 Heat

-

C

-

-

-

119

OSO Hotwater AS

800 1354 MA 1000 Heat

-

C

-

-

-

140

OSO Hotwater AS

800 1356 MA 2000 Heat

-

-

-

-

-

-

OSO Hotwater AS

800 1357 MA 3000 Heat

-

-

-

-

-

-

OSO Hotwater AS

800 1358 MA 5000 Heat

-

-

-

-

-

-

OSO Hotwater AS

800 1363 MA 10000 Heat

-

-

-

-

-

-

OSO Hotwater AS

800 1253 MA 600 Cool

-

C

-

-

-

119

OSO Hotwater AS

800 1254 MA 1000 Cool

-

C

-

-

-

140

OSO Hotwater AS

800 1256 MA 2000 Cool

-

-

-

-

-

-

OSO Hotwater AS

800 1257 MA 3000 Cool

-

-

-

-

-

-

OSO Hotwater AS

800 1258 MA 5000 Cool

-

-

-

-

-

-

OSO Hotwater AS

800 1263 MA 10000 Cool

-

-

-

-

-

-

Summary of Contents for 800 1253

Page 1: ...r AS Industriveien 1 3300 Hokksund Norway Tel 47 32 25 00 00 Fax 47 32 25 00 90 E mail oso oso no www osohotwater com Maxi Accu MA 600 1000 2000 3000 5000 10000 l EN SAFETY INFORMATION O M INFORMATION...

Page 2: ...cts covered by these instructions 6 3 2 Included in delivery 6 3 3 Product dimensions 6 3 4 Requirements for installation location 7 3 5 Pipe installation 8 4 Initial commissioning 10 4 1 Filling with...

Page 3: ...ey are accessible for future reference The manufacturer assumes compliance by the end user with the safety operat ing and maintenance instructions supplied and by the installer with the fitting man ua...

Page 4: ...h sufficient understanding CAUTION The product must not be exposed to frost over pressure over voltage or chlorine treatment See warranty provisions Maintenance settings should not be carried out by p...

Page 5: ...30 EU Pressurised equipment PED 2014 68 EU The safety valve s used must be CE marked and conform to PED 2014 68 EU NRF no Product code Capacity persons Weight kg Diameter x height mm Freight vol m Hea...

Page 6: ...ument 2 1 All dimensions in mm C A B Product A B C D E MA 600 1930 1495 375 780 MA 1000 2130 1650 440 1000 MA 2000 2470 1650 405 1300 MA 3000 2725 1710 465 1500 MA 5000 3210 1700 MA 10000 4430 2000 Ma...

Page 7: ...wetroom standard latest TEK Alternatively fit an automatic stop valve with sensor and overflow from safety valve to drain The product should be placed in a dry and permanently frost free position The...

Page 8: ...n 1000 l 4 To order Return 2000 10 000 l 3 5 Pipe installation 3 5 1 Incoming water pressure The product is designed for a max operating pressure of 6 bar 3 5 2 Fitting pipes A Run a pipe of suitable...

Page 9: ...uctions 3 5 5 Fitting recommendation CAUTION The product should be placed in a room with a drain in accordance with the wetroom standard latest TEK Alternatively fit an automatic stop valve with senso...

Page 10: ...the product B Open the water supply to the product When water flows out of the venting point the tank is full and the vent can be sealed 4 2 Control points A Check that all pipe connections to from th...

Page 11: ...in force at the time of installation The Product has not been modified in any way tampered with or subjected to misuse and no factory fitted parts have been removed for unauthorized repair or replacem...

Page 12: ...r beskyttet av ndsverksloven og skal ikke reproduseres eller distribueres uten skriftlig avtale med produsenten Forandringer forbeholdes This installation manual and all its content is protected by co...

Reviews: