3.4 Requirements for installation location and positioning
!
CAUTION
!
The product shall be fitted in accordance with Part G3 of building regulations.
Liability for consequential damage will only apply if this is followed.
!
The safety valve supplied must be mounted on the cold water supply to the boiler. See
section 3.5.2.
!
The product shall be placed in a dry and permanently frost-free position.
!
The product shall be mounted on a wall suitable for the total weight of the product in operation.
!
If the product is fitted horizontally, the pipe connectors must point straight up.
It is
recommended that the product be screwed tight to the wall or a suitable surface regard-
less of the method chosen; use the screw holes (D).
If the product is fitted vertically, the electric box must face upwards. See page 8.
!
The product shall be mounted to allow access to the junction box when needed. Mains cable
can be placed in the channels in the back of the product. Mains cable for wall socket should be
laid where it is not exposed to any mechanical or chemical influence.
!
The product shall be easily accessible in the home for servicing and maintenance.
completely fitted, the product will not achieve
the specified ErP energy rating. The energy con-
sumption of the product could increase.
3.3.3 Wall fitting
The product is designed to be mounted on a wall.
When the insulation cap is removed, there is easy
access to the screw holes (D).
The Nano is attached to the wall with the sup-
plied fastening metal band (V); see illustration.
The metal band is bent/placed around the mid-
dle of the tank and fixed to the wall through the
holes in the insulation, using the screws/washers
supplied. Ensure that the connectors do not press
on the insulation parts. Use a torx type bit (T25).
Tighten the screws until the insulation around the
screw holes deforms slightly.
3.3.4 Reversing the inner tank
For horizontal mounting, the inner tank can be
reversed if it is desirable to swap the CW and HW
connections for ease of fitting. Important: This
can only be done when the electricity is not con-
nected.
1.
Remove the insulation (see 3.3.2).
2.
Remove the electrical cover by loosening
the nut (E). Then unscrew the strain reliever
for the mains cable (F) and remove the elec-
trical cover.
3.
The electrical cover (I) may be modified by
opening the alternative fixing for the strain
reliever (K). Material in the recess should be
removed and the strain reliever with cable
E
H
H
K
F
J
G
I
fitted into the new channel.
4.
Remove the fastening band (V). Pull the tank
out so the connections clear the attachment
points (H). Turn the tank 180° and push it
back into the attachment points. Refit the
fastening band.
5.
Ensure that connections and the coloured
rings (red/blue) indicating HW and CW are
positioned correctly in the slots.
6.
Fit the electrical cover with the nut (E), then
fit the insulation cap. The end-parts of the
insulation must now swap places.
7.
The product has built-in channels in the
back (J) for simple and tidy routing of the
mains cable at the back of the product.