USER MANUAL FOR THE OSMIO INFINITY HYDROXY GAS/WATER PRODUCTION ELECTROLYSIS SYSTEM
40
Red low level light is on and
alarm is sounding
The liquid level is too low, top it up with the water
from Humidifier - 1 and ensure Humidifier - 1 is
topped back up to the fill line with 0 TDS/distilled
water before use.
There are liquid droplets inside
the Tower Cap
The purpose of the Tower Cap is to allow mist
(containing lye) to separate from the gas. You will
see liquid droplets condense on the inside of the
Tower and that is the only ’water’ you should ever
see.
There is water in the Tower
Cap
Filling the tower cap too fast can create a gas lock at
the bottom of the Tower Cap. If you are filling the
system and the water level is still low but water is
seen in the Tower Cap, stop filling the machine and
start gas production. The gas being produced will
disturb the water in the Tower Cap and the water will
flow back into the system. You will then see the
water level in the system rise
No light on the main power
switch
Check the machine is properly plugged in. Check the
power cord is firmly attached to the back of the
system. If the power switch is still not lighting up,
then replace the 10 AMP fuse (do not fit a higher
rated fuse). If after completing all these actions the
issue is not resolved, then contact Osmio Solutions.
The green gas production light
comes on but does not stay on
You have a blockage in your gas tubing. Find the
blockage (this may be due to a kink in the tubing or a
plugged bubbling stone).
The green gas production light
is flickering rapidly on and off
You may have a partially clogged gas tube(s) or
require a pressure switch rest. Check for plugged
tubes or bubbling stone. Contact us for un-plugging
instructions. If the tubing is all clear contact us for
assistance to reset the pressure switch.