USER MANUAL FOR THE OSMIO INFINITY HYDROXY GAS/WATER PRODUCTION ELECTROLYSIS SYSTEM
16
●
Repeat with the two screws at the front of the top of the system, place handle in
place and screw in position using the screws
●
Unscrew black fill cap from the system and prepare the exposed threads by
wrapping 7 - 8 rounds of polytetrafluoroethylene (PTFE) tape clockwise around
the threads on the top of the system
Step 4 Filling the System
Cover the surface before pouring the lye solution into the system to prevent surface
damage (in case there is a leak caused by shipping damage or accidental spillage).
Before you pour the lye solution into the infinity, please flush the system with hot tap
water to dissolve any residual lye crystals. All systems are tested immediately prior to
the despatch, but crystallisation can occur during the shipment.
●
Insert power cable at back of system and plug in
●
Turn the system on so that the front display is illuminated
●
Place the funnel in the top of the system
●
Slowly pour in HOT tap water (approximately 65C, 1250 ml)
●
Check the sight tube to see the water level in the system (do not overfill)
●
Allow the water to cool before discarding from the system (down the sink)
●
Place the funnel back in the top of the system
●
Slowly pour the cooled lye (electrolyte) solution into the
system
●
Check the sight tube to see the electrolyte level within the
system
●
Measure another 500 ml of 0 TDS water and slowly add
this to the system
●
The system should not fill all the way, but this is the
recommended volume for first operation
The blue LED (bottom of the sight tube) and floating sight tube ball makes
it easier to see the liquid level (the ball can temporarily get stuck as
detailed above). The system should be operated 80-100% full to avoid
crystallisation of lye in a sight tube. The ball being stuck is inconvenient
but is not a warranty issue as it does not affect the performance of the system.
Do not
put concentrated lye solution through the tower cap check valve.