With the softener inlet and outlet valves closed - open the Bypass valve - now open 
the stop cock. 
 

Installation of Waste/Drain 
 

The flexible drain/waste tubing provided should be connected to the drain/waste 
outlet and the tubing should be run to either an “up-stand” or “outside” drain – 
there should be a 20mm “air gap” to prevent backflow at the exit of the drain/waste 
tube.   
 
The drain/waste tube should be as short as possible and should run upwards to a 
maximum of 1 meter.   If an extended run of more than 6 meters is required, then it 
should be connected to a larger diameter pipe. 
 

Connection of Overflow 
 

The overflow connection is “to the left handside” of the main body of our softener – 
run this downwards to an external drain. 
 

Connection of Electric Power 
 

The transformer should be connected to an electrical power supply (continuous) 
using the transformer and plug supplied and fitted.  
 
Our softener is pre-programmed, see programming instructions for setting the clock. 

 
Commissioning Our Softener 
 

Add some salt into the “brine” tank, do not allow the salt level to exceed  the 
overflow level then put/pour 5 -10 litres of water into the brine well and allow this 
to soak to create brine for 2-3 hours, then set the clock on our softener. 
 
Press the “Regen” button, this will put our softener into an immediate  
Regeneration – this initial regeneration will purge air from the system and confirm 
that all cycled are being followed. 

 
 
 
 

Summary of Contents for EcoSoft PREMIER

Page 1: ...EcoSoft Water Softener General Installation Guide...

Page 2: ...r unless an existing softener is being replaced This should be installed by an experienced DIYer or competent plumber either or both should have the necessary skills Positioning Of Our Softener Our so...

Page 3: ...ure that everything is to hand for a typical installation Water Pressure High or low water pressure can result in either damage to or failure of our softener Our softeners are tested to a pressure of...

Page 4: ...Prior to Installation Ensure mains water stop cock is closed off position...

Page 5: ...h of hose required 0 75 m 1m or 1 25m Finding the right kit for your home water softener Standard 15mm Water Softener Installation Fitting Kit use this kit where the plumbing system is standard 15mm m...

Page 6: ...erflow connection is to the left handside of the main body of our softener run this downwards to an external drain Connection of Electric Power The transformer should be connected to an electrical pow...

Page 7: ...l lead to savings over time 2 Time Clock Based Water Softeners Time clock water softeners are different from metered water softeners as they regenerate on a calendar basis when you set it to do so rat...

Page 8: ...due to faulty pipework i e restrictions in service flow drain and brine lines these should be fitted without and restrictions Need Help Call or email us Osmio Water Sales Support Line 01322 401 345 Ou...

Page 9: ...a larger volume of salt for even greater convenience Specification 8 litre Cabinet Softener Unit 8 x 17 Mineral Tank NSF Certified Mineral Tank Clack 1 Time Clock or Metered Softener Valve 8 litres Ca...

Reviews: