Plumbing of Our Softener
Complete the plumbing as per the above schematic – Use our fitting kits when
ordered.
Please ensure that you select the correct kit for your requirements. Things to
consider
1) Vented or Unvented Hot Water System?
Do you have a hot water tank system or a combi boiler? Unvented cylinders work
directly from the mains water supply and are essentially a hot water storage
cylinder, whereas vented cylinders are connected, via a vent pipe, to the cold water
storage tank which is usually located within the loft space of most properties.
2) Mains pipe size - 15mm, 22mm or more?
3) Length of hose required? 0.75 m, 1m or 1.25m.
Finding the right kit for your home water softener:
•
Standard 15mm Water Softener Installation Fitting Kit - use this kit where the
plumbing system is standard 15mm main with cold water storage tanks in the
loft.
•
Hi-Flo 15mm Water Softener Installation Fitting Kit - use this kit where the
plumbing system is standard 15mm main and where the plumbing system
utilises a combi boiler.
•
Hi-Flo 22mm Water Softener Installation Fitting Kit - use this kit where the
plumbing system is 22mm main with an unvented (megaflow type) hot water
system,
•
Hi-Flo 28mm Water Softener Installation Fitting Kit - use this kit where the
plumbing system is 28mm main with unvented (megaflow type) hot water
system and softener has 1" connections.
Hose length options are available for each kit.