SECTION 3 - MACHINE CONTROLS AND INDICATORS
3120774
– JLG Lift –
3-3
3. HYDRAULIC RESERVOIR/CIRCUIT BREAKER/FUSE
(located inside ground control station housing)
The hydraulic reservoir is housed inside the ground con-
trol station, the hydraulic oil level can be checked through
an access hole in the side of the cover. Maintain an oil
level to the "Fill to Line" indicator on the side of the reser-
voir.
NOTE:
Check hydraulic oil only when platform is completely low-
ered and after cycling platform up/down a few times.
A 5 Amp fuse is located inside the ground control station.
4. MANUAL DESCENT
VALVE
Knob
This
(RED)
knob, located under the base frame at the rear
of the machine,
provides for lowering of
the platform in the event of an emergency or power failure.
To operate PULL knob to LOWER platform, RELEASE
knob to STOP lowering.
Figure 3-2. Manual Descent Valve Location.
MANUAL DESCENT
VALVE KNOB
LOCATION
PULL TO LOWER PLATFORM -
RELEASE TO STOP LOWERING