background image

Installation- and Operating Instructions

    

SAUNA 

exclusiv

 9kW

Sauna control 400V

Art.Nr. 3112600003

Function:

The electronic control unit Sauna-exclusiv consists of a power component and of a flat
control panel intended for surface mounting. In the power component there are all
connections for the power supply connections, the sauna heater, the ventilator, the cabin
lighting, the sensor and for the control panel. The power component controls the
temperature in the sauna cabin within the range of 70°C to 110°C. For safety reasons the
maximum temperature in the cabin is limited to 139°C by an additional temperature fuse.
The built-in counter timer enables an automatical switching on of the heating to an
adjustable point of time for a heating period of max. 6 hours. The heater, the cabin lighting
and the ventilator may be switched on- and off on the control panel. The temperature
selection as well as the setting of the counter timer are also operated on the control panel.
Any operational information is displayed on the display of the control panel.

Technical Specification:

Dimensions:

Power component:

220x218x108mm³

Control unit:

194x157x23mm³

Operating voltage:

3N AC 400V

Control power draw:

ca. 6VA

Breaking capacity:

9kW (AC1)

Control range:

70-110°C

Temperature limit:

139°C

Protection type:

IP 44 (splash-proof)

Ambient temperature:

0-40°C

Fitting:

According to their protection type both the control unit and
the operating unit are to be fitted 

outside 

the sauna cabin to

be protected against damp. The operating panel must be
fixed near the sauna cabin door.
According to the accompanying drawing the temperature
sensor should be side-mounted to the heater near the cabin
ceiling. The side clearance to the middle of the heater
should be around 500mm. The clearance to the ceiling
should not exceed 200mm. You should avoid placing the
sensor near the exhaust opening or the door as well as near
the cabin corner.