OSF 3104811211 Installation And Operating Instructions Manual Download Page 12

Operating instructions EUROTRONIK-20    Page: 12 

1.  The following display appears after pressing the key 

 

 

 

 

 

Heater:            OFF
Manual control
of contact betw.
terminals 3+5.

 

2.  The heater can be enabled with the key 

 (K3 closed) and disabled again with the key 

 (K3 open). 

3.  The normal diagnostics display reappears when the key 

 is pressed again. 

Filter pump 

This line shows whether the relay K2 is on. This relay is used to switch the filter pump on or off. 

The following displays are possible: 

Filtration: OFF 

The filter pump is switched off (K2 open) 

Filtration:  ON 

The filter pump is switched on (K2 closed) 

When the filter pump is shown in the 

top

 line of the service terminal, it can be switched on or off: 

1.  The following display appears after pressing the key 

 

 

 

 

 

Filtration:       OFF
Manual control
of contact betw.
terminals 2+4.

 

2.  The filter pump can be switched on with the key 

 (K2 closed) and switched off again with the key 

  

(K2 open). 

3.  The normal diagnostics display reappears when the key 

 is pressed again. 

Auxiliary pump 

This line shows whether the EUROTRONIK switches on an auxiliary backwash pump with the help of the 
contact K4. 

The following displays are possible: 

Backw.pump: OFF 

The pump is off (K4 open). 

Backw.pump:  ON 

The pump is on (K4 closed). 

When the auxiliary backwash pump is shown in the 

top

 line of the service terminal, it can be switched on 

or off: 

1.  The following display appears after pressing the key 

 

 

 

 

 

Backw.pump: OFF
Manual control
of contact betw.
terminals 6+7.

 

2.  The backwash pump can  be switched  on  with the key 

 (K4 closed) and switched off again  with the 

key 

 (K4 open). 

3.  The normal diagnostics display reappears when the key 

 is pressed again. 

Motor-operated valve 

This line shows whether a motor-operated valve is opened or closed by the relay contact K1. 

The following displays are possible: 

Motor valve:SHUT 

The motor-operated valve is closed, terminal U3 is live with mains power. 

Motor valve:OPEN 

The motor-operated valve is open, terminal U2 is live with mains power. 

When  the  motor-operated  valve  is  shown  in  the 

top

  line  of  the  service  terminal,  it  can  be  opened  or 

closed: 

1.  The following display appears after pressing the key 

 

 

 

 

 

Motor valve:SHUT
Manual control
of motorvalve on
terminals U2+U3

 

2.  The motor-operated valve can be opened with the key 

 and closed again with the key 

3.  The normal diagnostics display reappears when the key 

 is pressed again. 

Summary of Contents for 3104811211

Page 1: ...ump backwash pump or blower A connection for an external temperature regulator provides the possibility of heating the pool during the filtration times An internal latch makes sure that the heater wil...

Page 2: ...ntroller on off 7 Manual control of the filter pump 7 Setting the time 7 Programming the timer backwashing and clear rinsing times 8 Programming the timer filtration times 8 Backwashing manual 9 Empty...

Page 3: ...little adhesive or grease to facilitate mounting of the controller For later operation of the system it is immaterial whether the pin is loose because it is centred by the housing of the controller Pr...

Page 4: ...ral Valve with bayonet lock Replace slides if necessary Stick on spacer disks if necessary Mounting of the EUROTRONIK Press the two slides yellow or red in completely at the same time Place the contro...

Page 5: ...ocess In teh position Filter this contact is only closed during filtration time The contact K3 in the EUROTRONIK is only closed when the valve is in the final position Filter and the filter pump is ru...

Page 6: ...is first lifted Rotate Backwash The valve disk is turned into the position Backwash Lower Backwash The valve disk is lowered into the position Backwash 4 39 Backwash The backwashing cycle is running T...

Page 7: ...ff The EUROTRONIK is off The valve is in the position Filter Switch defect The bottom final position of the valve disk has not been detected The microswitch in the bottom part of the housing is possib...

Page 8: ...and the normal operating display appears again If backwashing times have already been programmed they can be deleted with the key 1 Press the key repeatedly until the backwashing time that is to be d...

Page 9: ...ycle is the same as that entered during programming of the timer This key can also be used to end a backwashing cycle already in progress Emptying the swimming pool When the key is pressed for longer...

Page 10: ...ation of the filter pump during the complete backwashing time b Intermittent backwashing with repeated switching on and off of the pump during the backwashing time for better loosening of the filter s...

Page 11: ...essure switch Switch status of a pressure switch connected to terminals 10 and 11 B fortnightly Switch position of the left DIP switch backwash fortnightly B interval Switch position of the right DIP...

Page 12: ...with the help of the contact K4 The following displays are possible Backw pump OFF The pump is off K4 open Backw pump ON The pump is on K4 closed When the auxiliary backwash pump is shown in the top...

Page 13: ...ff when the bottom final position is reached or the key is pressed again 4 The normal diagnostics display reappears when the key is pressed again Note The drain of the swimming pool must be installed...

Page 14: ......

Reviews: