background image

 

Installation and Operating Instructions PC-230-smart                                                                  Page

 6 (10)

 

Timer 

Operation 

Touchscreen 

 

Switching the PC-230-smart on and off 

 

Press the   button to switch on the unit. 

 

Press the   button to switch off the unit. 

Changing the operating mode of the filtration pump 

 

The  "

Filtration  pump"

  button  can  be  used  to  select  the  operating 

mode 

ON/ AUTO/ OFF

 

ON  

 runs continuously 

AUTO  

 runs under timer 

OFF  

 no filtering 

Press the   button to return to the home screen. 

Time of day 

Filter pump 

Operating mode: 

green  = ON 

grey 

= OFF 

red 

= Fault 

Water temperature 

Heater 

ON/OFF 

Main menu 

OFF 

Summary of Contents for 310.000.1230

Page 1: ...310 000 1230 Technical data Dimensions 220mm x 285mm x 85mm Operating voltage 230V 50Hz Power consumption of control unit 1 5VA approx Switching capacity Pump Heating max 1 0 kW AC3 max 0 4kW AC3 Deg...

Page 2: ...peration 6 Touchscreen 6 Switching the PC 230 smart on and off 6 Changing the operating mode of the filtration pump 6 Changing the heating operating mode 7 Setting the required temperature 7 Setting t...

Page 3: ...tout or flow sensor for additional protection against the heater overheating The touchscreen can be used to select the required pool temperature or to switch off the heating d Adjusting the system tim...

Page 4: ...nnecting a filter pump with speed control We have other controls in our range for this type of pump The factory inserted link between the two terminals labelled Th must be removed when connecting a sa...

Page 5: ...ease see Calibrating the temperature on page 8 The following table can be used for checking the temperature sensor Resistance values of the temperature sensor Temperature Resistance 20 C 5800 Ohm 25 C...

Page 6: ...utton to switch off the unit Changing the operating mode of the filtration pump The Filtration pump button can be used to select the operating mode ON AUTO OFF ON runs continuously AUTO runs under tim...

Page 7: ...decreases the required temperature The displayed value is saved automatically Press the button to return to the home screen Setting the time The clock time can be set by pressing the Time button Press...

Page 8: ...the language Press the Language button Press the individual button to select the required language The symbol identifies which language is currently selected Press the button to return to the Main me...

Page 9: ...ows to adjust the time difference The displayed value is saved automatically Press the button to return to the Time settings menu Change the network settings Press the Network settings button In the N...

Page 10: ...tructions PC 230 smart Page 10 10 PC 230 smart combined with NR 12 TRS 2 and EUROTRONIK 10 Subject to changes April 21 Water level controller for overflow pools with spillway Backwash controller EUROT...

Reviews: