HDX6811N/HDX6812N HD Audio De-embedder
User Manual
9
SW1 is a 16-position rotary switch, which is used to select the specific setting.
The selection range is: 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, A, B, C, D, E, F.
2. SW2
SW2 is a 3-position toggle switch, used to adjust the parameters of the setting made by SW1.
To keep SW2 at the position of “UP” or “DOWN”, the continuous adjustment can be
achieved.
3. SW3
Reserved.
Audio meter is superimposed onto the HDMI output. The users can monitor the 4-channel AES
audio output channel though the meter. The factory default is enabled, also the TC.
When set the parameter, the LED will show the module status.
3.2 Parameter settings
The module has Bank 0~2 3 type-status., and the detail information refers to Table 3-2. There are
16 options in every Bank. The 16-position corresponds to each parameter setup, the user can set
these parameters to control module, or monitor the module status.
Rotate the SW1 at the position of “0”. The position of “0” is always used to select BANK.
Turn SW2 up or down to select BANK.
Turn SW1 to the appropriate location, and then toggle SW2 to set the parameters.
3.2.1 Option Description
Below will describe the parameter and function of Bank 0~2.
HDX6811N
:
Table 3-1
Bank 0 parameter and function setup
SW1 Function
Options
Default
0
Bank Select
Bank 0~Bank 2
Bank 0
1
Video source select
SDI/HDMI/Fiber
SDI
2
Demux Err Ctl
Pass/mute
Pass
3
V-bit Mute
Disable/Enable
Disable
4
AES Lock Mode
None /DARS
None
5
AES 1 Bits
24bits/20bits
24bits
6
AES 2 Bits
24bits/20bits
24bits
7
AES 3 Bits
24bits/20bits
24bits
8
AES 4 Bits
24bits/20bits
24bits