DEC/DES6800 CVBS/SDI Converter - 10 -
SW1
Position
Function
Description
OSD
Text
Default
1
Selects the genlock
Mode
1:1 Genlcok Mode
Free Run/Ref/Input
(only for DES6800)
Ref
2
Adjust horizontal timing
1:2 H Phase
0~1715
(only for DES6800)
0
3
Adjust vertical timing
1:3 V Phase
0~524
(only for DES6800)
0
4
Turn freeze on or off
1:4 Freeze
On/Off
(only for DES6800)
Off
5
Select type of freeze
1:5 Freeze Mode
Field 1/Field 2/Frame
(only for DES6800)
Field 1
6
Enable or disable hot
switch
1:6 Hot Switch
Enable/Disable
(only for DES6800)
Enable
7
Select loss of video mode
1:7 LossVid Mode
Disp Test/Pass/Hot Switch
Hot
Switch
8
Turn TSG on or off
1:8 TSG
On/Off
Off
9
Select color bar or black
field
1:9 TSG Sel
Color Bar/Black
Black
A
1:A
Reserve
B
1:B
Reserve
C
1:C
Reserve
D
1:D
Reserve
E
1:E
Reserve
F
1:F
Reserve
Table3-4
Functional Parameters of Bank 1 (625 line rate)
SW1
Position
Function
Description
OSD Text
Default
0
Select bank
1:0 Bank Selection
Bank 0
1
Selects the genlock
Mode
1:1 Genlcok Mode
Free Run/Ref/Input
Ref
2
Adjust horizontal timing
1:2 H Phase
0~1727
0
3
Adjust vertical timing
1:3 V Phase
0~624
0