DEC/DES6800 CVBS/SDI Converter - 8 -
3.
First make sure that the frame stands firmly, and then pull gently the module along the slot out
of frame.
4.
Install the front panel.
Chapter 3 Operation and Control
I
n the chapter 3, the following topics on DES6800N are introduced:
User’s Control
Setting the Parameters
Setting the Jumper
User Control and Operating Instruction
Refer the Table for BANK to fulfill the function.
Figure 3-1
SW1 SW2 Location
Select the SW1 at the location“0”, and SW2 is used to select the BANK.
BANK Selection
SW1 has four BANK.
Set SW1 to the location 0, and location “0” is always used to select BANK.
Switch SW2 up or down to select BANK A.
Table3-1
BANK Select
BANK 0
BANK 1
BANK selected
Off
Off
0
Off
On
1
On
Off
2
On
On
3
The function of SW1 is set as default, refer to Table 3-1 for defaults:
1. SW1 Mode Selection
The switch of SW1 is a 16-position rotary switch and it is used to select the specific function.
The range for selection is: 0, 1, 2, 3. 4, 5, 6, 7, 8, 9, A, B, C, D, E, F.
2. SW2 Mode Selection
The Toggle Switch of SW2
The SW2 is a toggle switch that has 3 positions with auto returning back the middle position. And it is