JH-DC OPERATOR INSTALLATION GUIDE
TERMINAL CONNECTION DESCRIPTIONS
TERMINALS
FUNCTION
DESCRIPTION OF FUNCTION
24VAC
24VAC
Provides 24Volt AC power for accessories.
24VAC N
Note: DC models will NOT have 24Volt AC power available.
24VDC+
24VDC
Provides 24Volt DC power for accessories.
24VDC- COMM.
1 & 4
OPEN
Opens the operator. Several accessories such as button stations, keypads, trans-
mitters and card readers can be wired to open.
3 & 4
CLOSE
Closes the operator. Use caution when wiring accessories to these terminals.
The
door must be clearly visible from the location of any accessories wired to
close.
4 & 5
KEY SWITCH OR
Performs the single-button function which will alternate between open and close or
open, stop and close - depending on dip switch #3. (See page
13
for details.)
2 & 4
STOP
Stops the operator. If no stop button is used, a jumper is required across
2&4
.
4 & 6
REVERSE
This function will cause a reversal when the door is traveling closed and will travel
back to the fully open position. Loop detectors are often wired for reverse.
4 & 50
OPEN
This function works only while the operator is opening. Any signal to this function
will cause the door to stop, reverse a short distance, and then stop again. At this
time the auto close timer is disabled, and a renewed input will be required to start
the door again. Should the door be restarted and the signal occur again prior to
reaching a limit, the door will stop again, and this time will sound the emergency
alarm and lock out.
4 & 51
CLOSE
This function works exactly like the OPEN OBSTRUCTION, except that it will only
work in the closing direction.
4 & 11
SHADOW/HOLD
This function will keep the door in its fully open position while the signal is present.
This is typically used with a loop and loop detector to keep a door open while
vehicular traffic is passing through.
24VDC+ & 60
RUN/PRE-START
A 24Volt DC device such as a strobe light or alarm can be wired to these terminals.
Depending on dip switch #2, these devices will either begin two seconds before the
operator starts, or only while the motor is running. (See page
13
for details.)
OBSTRUCTION
OBSTRUCTION
SINGLE-BUTTON
You must follow all required safety precautions and instructions at all times. Review the safety brochure
included with the operator. If any pages are missing or unreadable, contact OSCO at 1-800-333-1717 to request
additional copies.
Never connect a button station within reach of the door.
Do not adjust the circuit board current sensing feature too high. It should be adjusted high enough to keep the
door from falsely triggering the sensing, but no higher than necessary for the door to operate. Do not defeat
the purpose of this function!
Although both open and close sensing is provided as an integral part of the door operator, OSCO always
recommends use of reversing edges and photo electric units.
Summary of Contents for JH-DC
Page 9: ...9 JH DC OPERATOR INSTALLATION GUIDE CONTROL and ACCESSORY CONNECTION ILLUSTRATIONS...
Page 10: ...10 JH DC OPERATOR INSTALLATION GUIDE CONTROL and ACCESSORY CONNECTION ILLUSTRATIONS...
Page 11: ...11 JH DC OPERATOR INSTALLATION GUIDE CONTROL and ACCESSORY CONNECTION ILLUSTRATIONS...
Page 12: ...12 JH DCOPERATORINSTALLATIONGUIDE CONTROLandACCESSORYCONNECTIONILLUSTRATIONS 1 06 6...
Page 18: ...18 JH DC OPERATOR INSTALLATION GUIDE...
Page 19: ...19 JH DC OPERATOR INSTALLATION GUIDE...
Page 20: ...20 JH DC OPERATOR INSTALLATION GUIDE...
Page 21: ...21 JH DC OPERATOR INSTALLATION GUIDE MODEL JH DCMECHANICAL PARTS EXPLODED VIEW...