JH-DC OPERATOR INSTALLATION GUIDE

TERMINAL CONNECTION DESCRIPTIONS

TERMINALS

FUNCTION

DESCRIPTION OF FUNCTION

24VAC

24VAC

Provides 24Volt AC power for accessories.

24VAC N

Note: DC models will NOT have 24Volt AC power available.

24VDC+

24VDC

Provides 24Volt DC power for accessories.

24VDC- COMM.

1 & 4

OPEN

Opens the operator. Several accessories such as button stations, keypads, trans-
mitters and card readers can be wired to open.

3 & 4

CLOSE

Closes the operator. Use caution when wiring accessories to these terminals. 

The

door must be clearly visible from the location of any accessories wired to
close.

4 & 5

KEY SWITCH OR

Performs the single-button function which will alternate between open and close or
open, stop and close - depending on dip switch #3. (See page 

13

 for details.)

2 & 4

STOP

Stops the operator. If no stop button is used, a jumper is required across 

2&4

.

4 & 6

REVERSE

This function will cause a reversal when the door is traveling closed and will travel

back to the fully open position. Loop detectors are often wired for reverse.

4 & 50

OPEN

This function works only while the operator is opening. Any signal to this function
will cause the door to stop, reverse a short distance, and then stop again. At this
time the auto close timer is disabled, and a renewed input will be required to start
the door again. Should the door be restarted and the signal occur again prior to
reaching a limit, the door will stop again, and this time will sound the emergency
alarm and lock out.

4 & 51

CLOSE

This function works exactly like the OPEN OBSTRUCTION, except that it will only
work in the closing direction.

4 & 11

SHADOW/HOLD

This function will keep the door in its fully open position while the signal is present.
This is typically used with a loop and loop detector to keep a door open while
vehicular traffic is passing through.

24VDC+ & 60

RUN/PRE-START

A 24Volt DC device such as a strobe light or alarm can be wired to these terminals.
Depending on dip switch #2, these devices will either begin two seconds before the
operator starts, or only while the motor is running. (See page 

13

 for details.)

OBSTRUCTION

OBSTRUCTION

SINGLE-BUTTON

You must follow all required safety precautions and instructions at all times. Review the safety brochure
included with the operator. If any pages are missing or unreadable, contact OSCO at 1-800-333-1717 to request
additional copies.

Never connect a button station within reach of the door.

Do not adjust the circuit board current sensing feature too high. It should be adjusted high enough to keep the
door from falsely triggering the sensing, but no higher than necessary for the door to operate. Do not defeat
the purpose of this function!

Although both open and close sensing is provided as an integral part of the door operator, OSCO always
recommends use of reversing edges and photo electric units.

Summary of Contents for JH-DC

Page 1: ...TOR INSTALLATIONMANUAL January 2006 Rev 6 OPERATORSPECIALTYCOMPANY INC P O Box 128 Casnovia MI 49318 OSCO requires the use of a reversing edge or photoelectric control for pedestrian protection on all...

Page 2: ...ION The speed reduction is achieved by means of heavy duty sprockets and a roller chain which has been prelubricated at the factory LIMIT SWITCHES The limit switches are actuated by rotary motion of a...

Page 3: ...procket onto drive shaft and tighten set screw securely 6 Now position door shaft sprocket so it is exactly in line with the drive sprocket and tighten set screw securely 7 Slide 1 shaft collar onto d...

Page 4: ...wall construction prohibits the use of through bolts lag bolts and shields of sufficient size may be used At this point hand tighten the bolts only DRIVE CHAIN INSTALLATION 1 Slide the door sprocket a...

Page 5: ...eaded shaft Once the open limit nut is set repeat the above process for the close direction nut and LSC 1 limit switch After finishing the initial limit nut adjustments reposition the door to approxim...

Page 6: ...llation Adjust the torque limiter tight enough to keep it from slipping during normal operation To adjust the torque limiter in the Model JH DC 1 Loosen the jam nut 2 To increase the output turn the a...

Page 7: ...24VDC Over 350 ft use DC power 0 2000 14 Volts Maximum Distance ft Wire Gauge MODEL JH DC g n i r i W r e w o P s t l o V P H e c n a t s i D x a M l a u D e l g n i S e r i W e g u a G V 5 1 1 2 1 P...

Page 8: ...and ex pired This can be caused by having the timer set too low if a chain or belt is broken or if a sprocket or pulley is slipping When the timer expires the door stops and the stop button must be pr...

Page 9: ...9 JH DC OPERATOR INSTALLATION GUIDE CONTROL and ACCESSORY CONNECTION ILLUSTRATIONS...

Page 10: ...10 JH DC OPERATOR INSTALLATION GUIDE CONTROL and ACCESSORY CONNECTION ILLUSTRATIONS...

Page 11: ...11 JH DC OPERATOR INSTALLATION GUIDE CONTROL and ACCESSORY CONNECTION ILLUSTRATIONS...

Page 12: ...12 JH DCOPERATORINSTALLATIONGUIDE CONTROLandACCESSORYCONNECTIONILLUSTRATIONS 1 06 6...

Page 13: ...he auto close timer off on 2 This switch is used in conjunction with alarms and flashing lights that may be added to the operator When the switch is in the ON position these devices will start approxi...

Page 14: ...ould the door be restarted and the signal occur again prior to reaching a limit the door will stop again and this time will sound the emergency alarm and lock out 4 51 CLOSE This function works exactl...

Page 15: ...and make sure the door does not false trip in either direction MAXIMUM RUN TIMER ADJUSTMENT This adjustable potentiometer sets the maximum length of time the motor will run before shutting down It sho...

Page 16: ...lable the operator will continue to operate in battery only mode if the charger board is set in its RUN mode see Battery Backup Charger Configuration Accessories wired into the operator will continue...

Page 17: ...OP This indicator is lit when a shadow hold open signal is present This signal is generated by a loop detector wired to the shadow loop terminals These indicators are lit when the open limit switch is...

Page 18: ...18 JH DC OPERATOR INSTALLATION GUIDE...

Page 19: ...19 JH DC OPERATOR INSTALLATION GUIDE...

Page 20: ...20 JH DC OPERATOR INSTALLATION GUIDE...

Page 21: ...21 JH DC OPERATOR INSTALLATION GUIDE MODEL JH DCMECHANICAL PARTS EXPLODED VIEW...

Page 22: ...procket 41 B 9 5 8 bore 9B 2110 730 Clutch Hub with Shaft Assembly 9C 2300 168 Clutch Disc 9D 2220 026 Double Pulley 7 with Bearing 2200 230 Bearing 7 8 OD x 5 8 ID x 1 1 2 LTB 9E 2400 066 Flat Washer...

Page 23: ...t Wire Harness Assembly 11 2500 071 Terminal Strip 16 141 12 2510 249 Input Wire Harness Assembly 13 2500 2127 DC Charger Board REF NO PARTNO DESCRIPTION 14 2500 2018 15 Amp Fuse 15 2500 2019 20 Amp F...

Page 24: ...has two brushes one on each side Original brushes are approximately 3 4 long and should be replaced when they are 1 4 long or sooner If brushes are allowed to wear beyond this point permanent damage...

Reviews: