EL 36 & 50 Eco
9.5.6 Service (display)
Service is used for troubleshooting, diagnostics,
history, program updates and reset. To reset saved
operational history and the service timer, a 4-digit pin/
service code must be entered.
• Service code;
is received when the warranty
registration of the boiler is done. When entered
the grey (dim) alternatives in the menu may be
used.
• Write log to USB
; Write log file for trouble
shooting to connected USB. Is grey (dim) if no
USB is connected. (Yes/No)
Logs operational data, inputs and outputs to a file on
the usb memory every 30 seconds for 24h.
Is used by Osby Parca to make advanced analysis of
the boiler’s functions.
• Alarm dumps;
export the alarm log to USB for
trouble shooting.
• Function test
; see status of all inputs and
outputs. Inputs are grey and outputs white, the
white ones may be managed. When leaving the
menu the outputs revert to the status determined
by the regulator.
Further info in section
10.6
!
• SW update;
update the software from a USB
stick
(opens new menu)
• Backup/Restore defines and settings
(opens
new menu)
• Reset Highest flow temperature memory
(pin
code needed)
• Reset operating time counter
(pin code needed)
• Reset energy counter
(pin code needed)
• Reset history
(pin code needed)
• Service timer
; Shows remaining time to service
and allows you to set time for the next service.
When it's time for service, a yellow wrench
appears on the home page (pin code needed).
Also see chapter 4, Servicing.
Software update, USB
Backup/Restore defines and settings