Stratford
Fireplace Installation and Operation Manual
_____________________________________________________________________ 33
PART B
–
INSTALLATION
Install the fireplace only as described in these instructions and using only components from the
chimney manufacturers listed in table 2.
Parts Required
•
Stratford Fireplace
•
Insulated chimney made by the manufacturers listed in table 2, with the corresponding
specifications :
Chimney lengths
Elbows (where necessary)
Associated components as per these installation instructions
Additional Equipment (optional)
•
Forced air distribution kit
•
Hot air gravity distribution kit
•
Fresh air intake kit
•
Firescreen
6
SAFETY INFORMATION
6.1
SUMMARY OF INSTALLATION CAUTIONS AND WARNINGS
•
THE INFORMATION GIVEN ON THE CERTIFICATION LABEL AFFIXED TO THE APPLIANCE
ALWAYS OVERRIDES THE INFORMATION PUBLISHED, IN ANY OTHER MEDIA (OWNER’S
MANUAL, CATALOGUES, FLYERS, MAGAZINES AND/OR WEB SITES).
•
MIXING OF APPLIANCE COMPONENTS FROM DIFFERENT SOURCES OR MODIFYING
COMPONENTS MAY RESULT IN HAZARDOUS CONDTIONS. WHERE ANY SUCH CHANGES ARE
PLANNED, STOVE BUILDER INTERNATIONAL INC. SHOULD BE CONTACTED IN ADVANCE.
•
ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY THE
TESTING AUTHORITY VIOLATES CSA B365 (CANADA), AND ANSI NFPA 211 (USA).
•
CONNECTION BETWEEN A 2100 INSULATED CHIMNEY AND A LISTED STAINLESS STEEL
CHIMNEY LINER IS ALLOWED IF A LISTED CONNECTOR IS USED. FOLLOW INSTRUCTIONS IN
SECTION 9.9 FOR THAT KIND OF INSTALLATION.
•
IF REQUIRED, A SUPPLY OF COMBUSTION AIR SHALL BE PROVIDED TO THE ROOM.
•
DO NOT CONNECT TO OR USE IN CONJUNCTION WITH ANY AIR DISTRIBUTION DUCTWORK
UNLESS SPECIFICALLY APPROVED FOR SUCH INSTALLATION.
•
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
•
THIS FIREPLACE HAS NOT BEEN TESTED TO BE INSTALLED IN A MOBILE HOME.
•