Page 1: ...by STOVE BUILDER INTERNATIONAL INC 250 de Copenhague Saint Augustin de Desmaures Quebec G3A 2H3 After sale service 418 908 8002 E mail tech sbi international com www osburn mfg com This manual is avai...

Page 2: ...1 RELOADING 21 CREOSOTE FORMATION AND NEED FOR REMOVAL 22 ASH DISPOSAL 22 MAINTENANCE 23 GLASS 23 GASKETING 23 PAINT 23 SECONDARY AIR TUBE REPLACEMENT 24 EXPLODED DIAGRAM AND PARTS LIST 25 OSBURN LIMI...

Page 3: ...is not properly installed a house fire may result To reduce the risk of fire follow the installation instructions Failure to follow instructions may result in property damage bodily injury or even de...

Page 4: ...e fuel type and other variables The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in...

Page 5: ...andard safety UL 1482 UL 907 Canadian standard safety ULC S628 East west through the door you see the longitudinal sides of the logs north south through the door you see the tips of the logs Mobile ho...

Page 6: ...6...

Page 7: ...DRAPES WELL AWAY FROM THE INSERT NEVER USE GASOLINE GASOLINE TYPE LANTERN FUEL KEROSENE CHARCOAL LIGHTER FLUID OR SIMILAR LIQUIDS TO START OR FRESHEN UP A FIRE KEEP ALL SUCH LIQUIDS WELL AWAY FROM TH...

Page 8: ...need to install the door overlay See figure 1 below for installation instructions Position the overlay on the door frame and fix it in place from behind using the 4 screws Note It is not necessary to...

Page 9: ...djusted periodically to provide an air tight fit To adjust Remove the lock pin spring pin by pulling and turning it using pliers wise grip Turn the handle counter clock wise one turn to increase press...

Page 10: ...eets the manufacturer s specs and code conformity The chimney must be of at least 1 25 mm larger in diameter to accommodate a required continuous stainless steel liner running from the flue collar to...

Page 11: ...r fireplaces are of adequate construction 7 OPENING SIZE Refer to Suitable Fireplace Dimensions for suitable size fireplace openings 8 The flue pipe must not go through roof trussing an attic a wardro...

Page 12: ...mm Note 1 I 8 203 mm N A Canada only J N A USA only 8 203 mm Note 1 From door opening The depth of a non combustible shelf in from of the insert is included in the calculation of the floor protector s...

Page 13: ...in the chimney Chimneys constructed outside of the home on an exterior wall should be avoided if possible especially in colder climates Outside chimneys may not draw as well and may downdraft due to...

Page 14: ...the extreme positions and to use the adjustability of the faceplate to take up any inaccuracies in the fit Alternatively the plate itself can be moved up and back by using a 6 152mm extension directl...

Page 15: ...on chosen will depend on your own preference for most installations where the lintel is less than 6 152mm and the depth is greater than 12 5 318mm See the table and Figure 5 Figure 4 Figure 5 MAXIMUM...

Page 16: ...e the faceplate face down on a flat nonabrasive surface see Figure 6 so that the sides are a bit towards the middle Figure 6 C Place the slide onto the faceplate so that the bends of the faceplate pie...

Page 17: ...p the eight faceplate trim clips in place see Figure 8 Figure 8 Figure 9 8 Lift the insert into the fireplace Square the insert to the face of the fireplace by adjusting the levelling legs on the side...

Page 18: ...st the fireplace facing See Figure 10 One 7 16 11mm open end wrench should be used to turn the nut B located above the cooktop in the center up so that it securely fastens the adjustable faceplate sle...

Page 19: ...d must have dried for 9 to 15 months such that the humidity content in weight is reduced below 20 of the weight of the log It is very important to keep in mind that even if the wood has been cut since...

Page 20: ...ss is not toxic Never start your insert outside You will not be able to see if you are over heating IGNITION After making sure that the insert air intake controls are fully open place several rumpled...

Page 21: ...losing the air control too soon will lower combustion efficiency and may cause the fire to die out The addition of a blower if not already included is highly recommended to maximize your unit s effici...

Page 22: ...ures The secondary combustion can only take place if the firebox is hot enough Always check for creosote deposit once every two months and have your chimney cleaned at least once a year ASH DISPOSAL A...

Page 23: ...t may scratch Use a specialized product available in the stores where wood inserts are sold The glass should be washed only when cold GASKETING It is recommended that you change the door gasket which...

Page 24: ...ft to remove 4 Reassemble in reverse order using a new cotter pin The cotter pin is a hammerlock style and locks into place by hitting the head sharply with a hammer 5 Note that any tube can be replac...

Page 25: ...25 EXPLODED DIAGRAM AND PARTS LIST...

Page 26: ...A X 1 1 2 L 1 10 SE34103 REPLACEMENT GLASS WITH GASKET 10 1 8 X 16 1 8 1 11 AC06400 3 4 FLAT X 6 BLACK SELF ADHESIVE GLASS GASKET KIT 1 12 SE34060 GLASS RETAINER FRAME WITH GASKET 1000 1100 1600 SERIE...

Page 27: ...USHED NICKEL FACEPLATE TRIMS 29 X 44 1 34 PL36046 4 1 2 X 9 X 1 1 2 X 1 1 2 REFRACTORY BRICK 2 35 29020 4 1 2 X 9 X 1 1 4 REFRACTORY BRICK HD 6 36 PL36021 2 1 8 X 9 X 1 1 4 REFRACTORY BRICK 2 37 PL360...

Page 28: ...t The manufacturer may at its discretion fully discharge all obligations with respect to this warranty by refunding the wholesale price of any warranted but defective parts The manufacturer shall in n...