Section 5.0 Troubleshooting
Symptom
Possible Cause
Corrective Action
I
Smoke in room
1. Down
draft
1. Upgrade
chimney
2. Chimney
blocked
2. Clean
chimney
3.
Chimney damper shut
3.
Open or remove damper
4.
Baffle out of position
4.
Correctly position baffle
5.
New paint is curing
5.
Refer to instructions
II Wood
burns
poorly or is slow
to start or no
heat
1.
Low
draw
2.
Wet or decayed wood
3.
Blocked intake air
1.
Upgrade
chimney
2.
Use proper fuel
3.
Check intake air supply by
removing fan from insert
and opening a window
III Dirty
glass
1.
Insert is being under fired
1.
Refer to instructions
IV
Wood burns too
fast
1.
Too much draft in
chimney
1.
Consult a qualified
technician.