8. Do not use makeshift compromises during installation, as they could create a safety hazard and a fire
could result.
9.
DO NOT CONNECT THIS APPLIANCE TO THE CHIMNEY OR FLUE SERVING ANOTHER
APPLIANCE.
2.4 Installation Instructions
1. Inspect the fireplace according to the safety information and fireplace requirements and have it
cleaned and/or upgraded as necessary.
2. If the installation of the unit renders the existing damper control inaccessible, it will be necessary to
either secure the damper wide open or remove it entirely. An inaccessible damper, which may close,
could cause smoke to enter the room. This creates a potential health hazard.
3.
CONNECTOR INSTALLATION:
A flue connector may provide acceptable performance, however,
we recommend the use of a chimney liner to ensure satisfactory performance. Slip connectors for
continuous liners should also be installed. Use Listed Chimney Liners – UL1777, CAN/ULC-S635.
4.
ATTENTION INSTALLER:
When positioning the unit in a fireplace opening prior to the flue
installation, install the insert into the opening until the top lip of air jacket is flush with fireplace
facing.
Figure 2.2
Figure 2.3
4. If lag-bolts and anchors are to be used to secure the insert, the hole locations should be marked
with the unit in place. Remove the insert and locate the anchors.
5. Remove the faceplate panels from their box and assemble according to the following
instructions.