GENERAL SAFETY
•
To reduce the risk of injury, close supervision is
necessary when a product is used near children. Do
not allow the pressure washer to be used by children
or people who are not familiar with it.
•
Know how to stop the product and bleed the pressure
quickly by pressing the trigger (See the ‘Operation’
section on page 5). Be thoroughly familiar with the
controls.
•
Stay alert and watch what you are doing.
•
Do not operate the product when tired or under the
influence of alcohol or drugs.
•
Keep operating area clear of all people and clutter.
•
Do not over reach or stand on an unstable support.
Keep a good footing and balance at all times.
•
This product must be grounded. The plug must be
plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local
codes and ordinances. Check with a qualified
electrician if you are in doubt as to whether the outlet
is properly grounded.
•
When working outdoors only use suitably approved
extension cables with a minimum conductor cross
section of 1.5mm
2
. The plug connectors must have
earthing contacts and be waterproof. Always
disconnect the extension from the mains electricity
supply, before disconnecting the pressure washer
from the extension cord.
•
Do not start and run the machine in the rain or stormy
conditions. Keep all connections dry and off the
ground. Do not touch the plug or sockets with wet
hands. It is very important not to let water leak into
the machine.
•
The machine should be switched off if it is not used
for periods longer than 3 minutes.
•
Maintain a constant water supply when the machine
is running. Without water circulation damage will be
caused to the sealing rings of the machine.
•
It is necessary to turn on the spray lance within one
or two minutes after the machine has been started.
Otherwise, the temperature of the circulating water
within the machine will soon rise to a critical point,
which will cause damage to the sealing rings inside
the machine.
•
Do not start and run the pressure washer in a place
which is excessively cold.
•
This machine has been designed for only using
cleaning water. Do not use corrosive chemicals.
•
This machine must be connected to a cold water
source.
•
Hold the spray lance firmly when in use as there is a
chance it might swing back with the force that is
inside it.
•
Do not use the appliance within the range of persons
unless they are wearing protective clothing.
•
Do not wash any objects which are a health hazard
e.g. asbestos.
•
High pressure jets can be dangerous if subject to
misuse. The jet must not be directed at persons, live
electrical equipment or the appliance itself. Pressure
washers should not be pointed less than 30cm away
from tyre walls or tyre valves, as it may be possible to
damage them.
•
Do not direct the jet against yourself or others in order
to clean clothes or footwear.
•
Disconnect from the electrical power supply before
carrying out user maintenance.
•
To ensure the appliance safety, please use only
original spare parts from Osaki. Do not use the
machine before you have changed them if they are
damaged.
•
Store the pressure washer in a dry, secure place,
away from children.
•
If the supply cord is damaged, it must be replaced
immediately.
•
Never try to move the appliance by pulling it with the
mains lead. Do not allow the mains lead to be pulled
around corners or sharp edges. Do not run the
pressure washer over the lead.
Repair work on the Osaki Power Washer can
only be carried out by a trained service engineer.
A comprehensive in house repair and service
facility is available through your local agent.
ACCESSORIES
7
TROUBLE SHOOTING
FAULT
When switched on,
the machine will not
start working.
Fluctuating pressure.
Water is leaking
from the pump.
The motor stops
suddenly.
The pump does not
reach the necessary
pressure.
LIKELY CAUSE
Plug is not well connected or electric socket is faulty.
The mains voltage is insufficient.
The pump is stuck.
Thermal safety switch has tripped.
The pump is sucking air.
The valves are dirty, worn out or stuck.
The pump seals are worn out.
The seals are worn out.
The thermal safety switch has tripped due to overheating.
The water inlet filter is clogged.
The pump is sucking air from connections or hoses.
The suction/delivery valves are clogged or worn out.
The unloaded valve is stuck.
The lance nozzle is incorrect or worn out.
SOLUTION
Check plug socket.
Check that the mains voltage is adequate.
Refer to after storage instructions.
Switch off the machine and let the motor cool for a few minutes.
Leave the lance open.
Check that hoses and connections are airtight.
Clean and replace, or refer to your dealer.
Check and replace, or refer to your dealer.
Check that the main voltage, corresponds to the specifications.
Switch off the unit and let it cool for a few minutes.
Clean the water inlet filter.
Check that all supply connections are tight.
Check that the water feeding hose is not leaking.
Clear or replace the valves.
Loosen and retighten regulation screw.
Check and/or replace.
The following accessories are available through your local Osaki distributor:
Gun and lance with adjustable spray pattern
Order Code: OSA-280-1701W
(As supplied with Model CPW090)
Gun and lance with adjustable pressure and spray pattern
Order Code: OSA-280-1710W
(As supplied with Model CPW110)
5m high pressure hose
Order Code: OSA-280-1711W
(Suitable for Model CPW110)
Osaki pressure washer accessory kit
Order Code: OSA-280-1705W
Kit Contents: 1 x Large round head brush attachment with rotating centre.
1 x Large tapered head brush attachment (Wash brush).
1 x Snap action tap connector.
1 x Female hose fitting (HPC connector).
1 x Sander blast kit (includes hose & sand probe).
1 x Turbo lance.
1 x Flexible snake hose.
1 x 6m water hose.