The Smoke-R detector (hereinafter referred to as the “detector”) is designed to detect a smoke

inside of protected objects and transmit this events to the Lun-R receiver that is connected to the
Lun control panel (more about for compatibility, see the documentation of the relevant control

panel).

Product is not equipped with built-in cameras and microphones, devices and units for

hidden video and audio recording.

2. Safety Precautions

Only the employees, familiar with the module design, instructed on the safety arrangements

shall be allowed to install, routinely maintain and repair.

The device does not have open live parts, representing the danger of electric shock to a per-

son. No safety ground.

3. Technical specifications 

The detector technical characteristics is shown in the Table 1.

Table 1. Technical characteristics

Characteristic

Value

Operating frequency range (depends of modification), MHz

433.05…434.79 or

868.70…869.20

Power radiated by the transmitter, mW

up to 10

The health test signals period, seconds

60

Threshold sensitivity, dB/m

0.14

Inertia of response, s

5

Main and backup power source type

CR123A battery

Battery voltage, V

2.2…3.2

The batteries predicted service life, years

10

Degree of protection provided by enclosure

IP20

Dimensions, mm

125*125*70

Weight, g

200

Smoke-R

Version en_2

3

Summary of Contents for Smoke-R

Page 1: ...ance with operating modes and conditions therefore this document require ments is mandatory Smoke Detector Smoke R Operation manual ORTUS Group Product Compatibility Table Compatible radio receiver Lu...

Page 2: ...cal specifications 3 4 How to use 4 4 1 Modes Indication 4 4 2 Binding 5 4 3 Operability check 5 4 4 Wireless signal strength 6 4 5 Installing 6 5 Maintenance 6 6 Operating conditions 6 7 Storage 7 8...

Page 3: ...all routinely maintain and repair The device does not have open live parts representing the danger of electric shock to a per son No safety ground 3 Technical specifications The detector technical cha...

Page 4: ...If the detector s inner chamber is very dirty the event chamber dust is generated If remove the detector from the mounting base the tamper alarm event is generated If the voltage of the main battery...

Page 5: ...tteries to the detector observing polarity BACKUP first then the MAIN 5 Switch the detector to the binding mode by short circuit the RESET contacts for 2 3 sec onds until the blinking green the signal...

Page 6: ...r housing including from the mounting base Also the illumination of this place should be minimal and the distance to sources of electromagnetic interference and heating appliances maximum The installa...

Page 7: ...eriod or insulators must be installed in the battery holders 8 Transportation 1 Detector transportation shall be carried out in the manufacturer s package 2 Detector is allowed to be transported by al...

Page 8: ...Manufacturer ORTUS Group 1 East Liberty 6th Floor Reno NV 89501 USA Tel 1 650 240 27 62 mail info ortus io http www ortus io Smoke R Version en_2 8...

Reviews: