background image

4. How to use

The  detector’s PCB and battery holder  are  placed in a plastic enclosure with a removable

cover (Figure 1).

A sensitivity switch, acoustic signal transducer, a tamper switch, a multi-color LED indicator

and 

RESET

 contacts to initiate the process of binding with the Lun-R receiver are placed on the de-

tector’s PCB.

Figure 1. Detector and its cover

Depending on external actions, the detector transmits the following events to the Lun-R re-

ceiver:

If no broken glass signal is detected, then the 

norm

 event is generated;

If the broken glass signal is detected, then the 

alarm

 event is generated;

If the housing cover is opened, the tamper will be triggered and the 

tamper alarm

 event

will be generated;

If the voltage of the main battery drops to 2.3V or lower – the event "

Main battery low

" is

generated;

If the voltage of the backup battery drops to 2.3V or lower – the event "

Bakup battery

low

" is generated;

GBD-R

Version en_2

4

Summary of Contents for GBD-R

Page 1: ...nce with operating modes and conditions therefore this document require ments is mandatory Glass Break Detector GBD R Operation manual ORTUS Group Product Compatibility Table Compatible radio receiver...

Page 2: ...echnical specifications 3 4 How to use 4 4 1 Modes Indication 5 4 2 Binding 5 4 3 Wireless signal strength 6 4 4 Installing 6 4 5 Adjusting 7 5 Maintenance 7 6 Operating conditions 7 7 Storage 8 8 Tra...

Page 3: ...install routinely maintain and repair The device does not have open live parts representing the danger of electric shock to a per son No safety ground 3 Technical specifications The detector technica...

Page 4: ...ing on external actions the detector transmits the following events to the Lun R re ceiver If no broken glass signal is detected then the norm event is generated If the broken glass signal is detected...

Page 5: ...ound when the binding is completed successfully turning on red for 2 3 seconds Settings flashing green every one second while the DIP switch 3 is on 4 2 Binding A new detector must be bound to the con...

Page 6: ...in order to form a reliable reception map 4 4 Installing To install the detector 1 Choose a place for installation at the height of 2m under the floor taking into account the signal strength in this p...

Page 7: ...able 2 Table 2 Ball deflection angle for detector setup Ball deflection angle Glass thickness mm 3 3 4 4 5 5 6 6 7 7 Ordinary glass 30 35 40 45 50 55 Tempered and laminated glass 45 50 55 60 65 70 8 I...

Page 8: ...period or insulators must be installed in the battery holders 8 Transportation 1 Detector transportation shall be carried out in the manufacturer s package 2 Detector is allowed to be transported by a...

Page 9: ...Manufacturer ORTUS Group 1 East Liberty 6th Floor Reno NV 89501 USA Tel 1 650 240 27 62 mail info ortus io http www ortus io GBD R Version en_2 9...

Reviews: