Status Display Codes

 

 

Below is a list of normal display codes which indicate the controller mode of 
operation.

 

 

IdLE - 

This is ready mode; No firing in process. This message will

 

alternate 

with the temperature display and/or any alarm messages that may occur.

 

 

dELA 

- This is the delay start mode. This message will alternate with the

 

delay time count-down if programmed.

 

 

Strt 

- This is a final prompt before starting a new firing. The Delay start

 

and 

Thermocouple Offset features are accessed from this prompt.

 

 

-On- 

- This is a short (5 second) display that indicates a new firing has

 

been started.

 

 

StOP 

- This is an Abort message; the firing was stopped early. This

 

message will alternate with the temperature display and/or any alarm 
messages that may occur.

 

 

CPLt 

-  This  is  a  firing  complete  message;  the  firing  ended  successfully.

 

This message will alternate with the temperature display and the total firing 
time from start to finish.

 

 

x-4 - 

This is a short (5 second) display of the Model number which

 

appears every time the controller is turned on.

 

 

Alarm Display Codes

 

 

In addition to Power failure alarms, these messages may be displayed if the 
controller detects a problem during the firing.

 

 

tC 

-

 

This alarm indicates that the thermocouple sensor is no longer

 

detected. The 

controller can not operate without a thermocouple signal. In most cases, the 
thermocouple has failed and will need replacement, or the electrical connections 
for the thermocouple may be loose or damaged. Check the wiring for the 
thermocouple and the physical condition of the probe inside the firing chamber.

 

 

tCr 

-

 

This alarm indicates that the thermocouple sensor is detected but

 

the signal 

is reversed. The firing was terminated. The thermocouple signal is a low voltage 
direct current with +/- polarity. The controller will sense that the temperature is 
traveling backwards from what is expected. In most cases, the thermocouple needs 
reconnected properly. Check the wiring for the thermocouple.

 

 

FAIL 

-

 

This alarm indicates that the thermocouple sensor is no longer

 

detected. 

The signal was lost during and active firing and the firing was terminated. The 
controller can not operate without a thermocouple signal. In most cases, the 
thermocouple has failed and will need replacement, or the electrical connections 
for the thermocouple may be loose or damaged. Check

 

 

8

 

 

An active delay time can be canceled by pressing the Program/Start 
button any time during the delay count-down to begin the actual firing.

 

 

Thermocouple Offset Option

 

 

Thermocouple Offset allows you to correct the temperature display a few 
degrees in a positive or negative direction. This can improve the controller 
accuracy if the thermocouple probe is aged or if the firing results appear to 
be slightly under or over fired. This offset allows you to make minor 
adjustments to the firing temperatures without changing the programmed 
heating or cooling temperatures.

 

 

Prior to the active start of any firing, the controller display will show a Start 
prompt of 

Strt

. This appears after the firing program selection and 

programming. If a thermocouple offset is desired, press the Increase/Option 
button to activate a thermocouple offset prompt. The display will show 

tCOS

 alternating with the adjustable offset value. Use the 

Increase/Decrease buttons to set the Offset and then press the Program 
button when you are ready to return to the 

Strt

 prompt.

 

 

Thermocouple offset (

tCOS

) has a limited offset range of +/-20°F (+/-11°C). 

A positive correction will increase the controller display temperature by the 
amount selected. This will make the firing temperatures lower. A negative 
correction will decrease the controller display temperature by the amount 
selected, making the firing temperatures higher.

 

 

Program Review

 

 

Any time during an active firing, the Program Review feature can be activated 
to show you the complete firing schedule on the controller display. Press the 
Decrease/Review button to activate the Program Review. Each segment of 
your firing schedule will scroll automatically on the display for a few seconds 
each. To cancel the Review in process, simply press any button.

 

 

Program Review can also be activated when the controller is 

IdLE

 or during 

program selection. After this type of Program Review, the controller 
advances directly to the 

Strt

 prompt. The Review can be used to bypass 

making any changes to the current firing schedule.

 

 

Program Recall

 

 

Program Review can be used to quickly select any firing schedule that is 
already programmed into the controller memory. To select a saved program, 
the controller should first be at the 

IdLE

 prompt. Press the Increase/Option 

button until the display shows the desired program, then press the 
Decrease/Review button to automatically load the program and to review the 
program settings. At the end of automatic program review, the controller will 
go directly to the 

Strt

 prompt and the firing can be started with one more 

press of the Start/Stop button. Only use the quick program recall to start a 
new firing if no changes are required for the entire firing program.

 

 

Options Menu

 

 

During an active firing, the Increase/Option button will activate an options 
menu and scroll through the available options with each button press. These

 

 

5

 