background image

rA1 = 0250

 

°F 1 = 0750

 

HLd1 = 00.00

 

rA2 = 0900

 

°F 2 = 1425

 

HLd2 = 00.30

 

rA3 = FULL

 

°F 3 = 1050

 

HLd3 = 00.00

 

rA4 = 0150

 

°F 4 = 0750

 

HLd4 = 00.00

 

rA5 = 0000

 

 

 

 

4. The display shows 

Strt

 after the final entry above.  

 

5. Press (Program) button one last time to start the firing. Display will show 

-

  

On- 

 

 

Heat Treating Program Example

 

 

Below is a typical 3 step firing schedule for Heat Treating Steel.

 

 

Step 1. Heat as fast as possible from starting temperature to 1800°F, Hold 

at 1800°F for 20 minutes

 

 

Step 2. Cool as fast as possible from 1800°F to 400°F, with no hold time at 

400°F

 

Step 3. Heat as fast as possible from 400°F to 500°F, Hold at 500°F for 5 

hours, and then Shut-off

 

 

To program this schedule from 

IdLE

 mode;

 

 

1. Press  (Program)  button.  The  controller  will  display  the  last  active 

program that was used. 

PrO1 

– PrO9

  

 

2. Press (Program) button again if you want to use the same program that 

is  shown  or  press  (Increase)  button  to  change  to  another  program  and 
then press (Program) button again.  

3. Program the steps below and press (Program) button after each segment.  

 

rA1 = FULL

 

°F 1 = 1800

 

HLd1 = 00.20

 

rA2 = FULL

 

°F 2 = 0400

 

HLd2 = 00.00

 

rA3 = FULL

 

°F 3 = 0500

 

HLd3 = 05.00

 

rA4 = 0000

 

 

 

 

4. The display shows 

Strt

 after the final entry above.  

 

5. 

Press (Program) button one last time to start the firing. Display will show 

-

 

 

On-  

 

 

 

 

 

 

 

 

 

 

 

 

 

12

 

 

 
 

Autofire

®

 Express

 

 

Ramp/Hold Controller

 

 

Instruction Guide

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

This button is for selecting a firing program and advancing 
through the programming steps. After programming is 
complete, use this button to Start and Stop the firing.

 

 

This button is used to change the firing program during 
programming and to change the display values for specific 
program settings. During a firing, use this button for special 
firing options (including Skip Step).

 

 

This button is used to change the display values for specific 
program settings. It is also used to activate the Program 
Review feature.

 

 

When using the Increase and Decrease buttons to 
change number settings, the values will change 
more rapidly if the button is held in.

 

 

1

 

Reviews: