7. Secure all internal wires and replace cover and

7.

secure cover screws

8. Turn ON AC line voltage supply

9. If the unit is supplied with a line cord, connect the

9.

line cord plug into the appripriate receptacle

9.

previously installed

10. If unit is complete with lamp heads, positioning the

10.

lamp heads to provide best lighting distribution by

10.

loosening head set screws to adjust angle and

10.

swivel. Manually rotate or turn head(s) to the

10.

desired position then tighten set screws to

10.

lock position

Conduit Stem

(not included)

Conduit

(not included)

Fig.3

Fig.5

Fig.4

Fig.6

IMPORTANT

Circuit feeding unit MUST be protected by 

lock-on breaker if breaker feeding this unit 

does not have a lock-on device (warranty 

will be voided if this is the case)

CAUTION

This equipment is furnished with a sophisticated low voltage battery 

dropout circuit to protect the battery from over-discharge after the 

useful output has been used. Allow 24 hours recharge time after 

installation or power failure for full-load testing or usage.

OPERATION & MAINTENANCE

Operation

1. To test, depress the TEST switch. Charge indicator will go out

and the DC lamps will come on

2. Release the TEST switch. DC lamps will be extinguished and the

charge indicator will come on

3. A bright charge LED indicator light indicates a high charge rate.

After the battery has reached full charge, the indicator light will
go out. Under normal operation, the high charge indicator will
turn ON and OFF intermittently while the unit is in standby
mode (regular AC is present) since the charge rate will vary in
order to maintain an optimal battery performance

Maintenance

1. Code requires that the equipment be tested every 30 days

for 30 seconds and that written records be maintained for
all test results and repairs. Further the equipment is to be
tested once a year for the required duration as per Code.
The battery is to be replaced or the equipment repaired
whenever the equipment fails to operate as intended
during the duration test. The manufacturer strongly
recommends compliance with all Code requirements.

2. Clean lenses on  a regular basis to provide maximum light

distribution in case of an emergency

IMPORTANT

The servicing of any parts should be performed by qualified service personnel only. 

The use of replacement parts not furnished by the manufacturer may cause equipment failure and will void the warranty.

LED 

Emergency Lights

MODEL 

O

E-212BP

INSTALLATION GUIDE

INSTALLATION GUIDE

Hardwired Installation

Junction

Box

Crossbar

Lamp

head

Cabinet

Battery

Cover

Tilt

Rotate 180º

Circuit Board

LED Indicator

Green: AC ON

Red: Charge

Test

LED 

Emergency Lights

MODEL

 

O

E-21

6-

150

W