INSTALLATION GUIDE

Connecting the Wires (choose A or B):

 A — One Cable (2-3 wires) Entering the Box

Connecting the Wires (choose A or B):

 B — 

Two cables (4 or 6 wires) Entering the Box

Connect the LINE cable wires to the LINE terminals:

The WHITE wire connects to the WHITE terminal (Silver)

The BLACK wire connects to the HOT terminal (Brass)

Connect the 

LOAD cable wires to the LOAD terminals:

Remove the yellow sticker to reveal the LOAD terminals

The WHITE wire connects to the WHITE terminal (Silver)

The BLACK wire connects to the HOT terminal (Brass)

Connect the grounding wires (only if there is a grounding wire):

Connect a 6" bare copper (or GREEN) 12 or 14AWG wire to the grounding
terminal on the GFCI. If the box has a grounding terminal, also connect a similar
wire to the grounding terminal on the box. Connect the ends of these wires to
the LINE and LOAD cable's bare copper (or GREEN) wire using a wire connector.
If these wires are already in place, check the connections.

Complete the installation:

Fold the wires into the box, keeping the
grounding wire away from the WHITE and HOT
terminals. Screw the receptacle to the box and
attach the faceplate

Go to the next step "Test Your
Work" (explained on the 

last

 page of this

instruction manual)

Receptacles

MODEL

 

MH

20

-ST

Summary of Contents for MH20-ST

Page 1: ...l electrical codes 2 A GFCI receptacle does NOT protect against circuit overload short circuits or shocks 3 In the event of a ground fault a GFCI will trip and quickly stop the flow of electricity to prevent serious injury 4 You can still be shocked if you touch bare wires while standing on a non conducting surface such as an wooden floor 5 For installation in wet locations protect the GFCI recept...

Page 2: ...tion A or B see the diagram below Procedure Box with Two Cables 4 6 wires a Detach one cable s white and hot wires from the receptacle and cap each one separately with a wire connector Make sure that they are from the same cable b Re install the receptacle in the electrical box attach the faceplate then turn the power ON at the service panel c Determine if power is flowing to the receptacle If so ...

Page 3: ...e WHITE wire connects to the WHITE terminal Silver The BLACK wire connects to the HOT terminal Brass Connect the grounding wires only if there is a grounding wire Connect a 6 bare copper or GREEN 12 or 14AWG wire to the grounding terminal on the GFCI If the box has a grounding terminal also connect a similar wire to the grounding terminal on the box Connect the ends of these wires to the LINE and ...

Page 4: ...red and powered the red LED d will flash one time within 5 sec and the internal self testing circuit d will launch every 1 10 min When the GFCI displays an alarm during d its operation the red light will turn ON immediately and it will no d longer provide a ground fault circuit protection reminding the user d that the GFCI is end of life and MUST be replaced e Press the TEST button then RESET butt...

Reviews: