background image

ICS Stand 2 

1108265B 

Advanced Measurement Technology, Inc. 

a/k/a/ ORTEC

®

, a subsidiary of AMETEK

®

, Inc.

 

WARRANTY 

 

ORTEC* warrants that the items will be delivered free from defects in material or workmanship. ORTEC makes no 
other warranties, express or implied, and specifically NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR 
A PARTICULAR PURPOSE. 

ORTEC’s exclusive liability is limited to repairing or replacing at ORTEC’s option, items found by ORTEC to be 
defective in workmanship or materials within one year from the date of delivery. ORTEC’s liability on any claim of 
any kind, including negligence, loss, or damages arising out of, connected with, or from the performance or breach 
thereof, or from the manufacture, sale, delivery, resale, repair, or use of any item or services covered by this 
agreement or purchase order, shall in no case exceed the price allocable to the item or service furnished or any part 
thereof that gives rise to the claim. In the event ORTEC fails to manufacture or deliver items called for in this 
agreement or purchase order, ORTEC’s exclusive liability and buyer’s exclusive remedy shall be release of the buyer 
from the obligation to pay the purchase price. In no event shall ORTEC be liable for special or consequential 
damages. 

 

Quality Control

 

Before being approved for shipment, each ORTEC instrument must pass a stringent set of quality control tests 
designed to expose any flaws in materials or workmanship. Permanent records of these tests are maintained for use 
in warranty repair and as a source of statistical information for design improvements. 

 

Repair Service

 

If it becomes necessary to return this instrument for repair, it is essential that Customer Services be contacted in 
advance of its return so that a Return Authorization Number can be assigned to the unit. Also, ORTEC must be 
informed, either in writing, by telephone [(865) 482-4411] or by facsimile transmission [(865) 483-2133], of the nature 
of the fault of the instrument being returned and of the model, serial, and revision (“Rev” on rear panel) numbers. 
Failure to do so may cause unnecessary delays in getting the unit repaired. The ORTEC standard procedure requires 
that instruments returned for repair pass the same quality control tests that are used for new-production instruments. 
Instruments that are returned should be packed so that they will withstand normal transit handling and must be 
shipped PREPAID via Air Parcel Post or United Parcel Service to the designated ORTEC repair center. The address 
label and the package should include the Return Authorization Number assigned. Instruments being returned that 
are damaged in transit due to inadequate packing will be repaired at the sender's expense, and it will be the sender's 
responsibility to make claim with the shipper. Instruments not in warranty should follow the same procedure and 
ORTEC will provide a quotation. 

 

Damage in Transit

 

Shipments should be examined immediately upon receipt for evidence of external or concealed damage. The carrier 
making delivery should be notified immediately of any such damage, since the carrier is normally liable for damage 
in shipment. Packing materials, waybills, and other such documentation should be preserved in order to establish 
claims. After such notification to the carrier, please notify ORTEC of the circumstances so that assistance can be 
provided in making damage claims and in providing replacement equipment, if necessary. 

 

 

Copyright © 2014, Advanced Measurement Technology, Inc. All rights reserved.

 

*ORTEC

®

 is a registered trademark of Advanced Measurement Technology, Inc. All other trademarks used herein are the property 

of their respective owners.  

NOTICE OF PROPRIETARY PROPERTY

 — This document and the information contained in it are the proprietary property of 

AMETEK Inc., ORTEC Business Unit. It may not be copied or used in any manner nor may any of the information in or upon it be 
used for any purpose without the express written consent of an authorized agent of AMETEK Inc., ORTEC Business Unit. 

 

Summary of Contents for ICS Stand II

Page 1: ...ORTEC Part No 1108265 Manual Revision B ORT X4548 ICS Stand II User Manual...

Page 2: ......

Page 3: ...n 865 483 2133 of the nature of the fault of the instrument being returned and of the model serial and revision Rev on rear panel numbers Failure to do so may cause unnecessary delays in getting the u...

Page 4: ...icates a hazard that could result in death or serious bodily harm if the safety instruction is not observed WARNING Indicates a hazard that could result in bodily harm if the safety instruction is not...

Page 5: ...ACKING THE ICS STAND 5 1 5 THE ICS STAND 6 2 ICS INSTALLATION ONTO THE ICS STAND 8 2 1 THE ICS AND ICS STAND ASSEMBLY 8 3 INSTALLATION UNDER A TYPICAL 4 TOP LOADING LEAD SHIELD 12 3 1 Preparing the le...

Page 6: ...CIFICATIONS1 1 1 1 Performance Maintenance The ICS Stand doesn t require periodic maintenance Consult the detector and ICS manuals for regular maintenance of the HPGe detector and the cryocooler 1 1 2...

Page 7: ...nents The ICS Stand main assembly User manual and documentation package Pneumatic air pump for units shipped after November 2015 1 4 UPACKING THE ICS STAND 1 Unpack the ICS Stand and make sure the sta...

Page 8: ...1108265B ICS Stand 2 6 1 5 THE ICS STAND Figure 1 illustrates the main features of the ICS Stand shown without the ICS and detector...

Page 9: ...ICS Stand 2 1108265B 7 Figure 1 ICS Stand 2 fully compressed Mount panel Air piston Schrader air valve Directional selection lever Adjustable feet 4 Plug support plate...

Page 10: ...ncluded One pneumatic air pump with a Schrader valve such as a bicycle pump included 2 1 THE ICS AND ICS STAND ASSEMBLY 1 Remove the plug support plate by lifting the plate off the main bracket no too...

Page 11: ...ICS Stand 2 1108265B 9 3 Flip the directional valve to the up position 4 Use the air pump to raise the platform about 6 inches 150 mm...

Page 12: ...1108265B ICS Stand 2 10 5 Place ICS on the platform ICS P4 shown...

Page 13: ...late No tools are necessary The plate slides into position Installation of the plate is meant to be snug If a secondary plug is not used it is not necessary to reinstall the plug plate NOTE The ICS an...

Page 14: ...y accommodate the size of the detector capsule and endcap 3 Verify the height of the shield bottom and or lip of the shield stand and whether or not the ICS Stand in the fully lowered position will ha...

Page 15: ...he detector capsule with the center of the access hole in the shield bottom 3 Once centered attach the pneumatic air pump move the directional selection lever on the front of the ICS Stand to the UP p...

Page 16: ...per position is reached Disconnect the pneumatic air pump and move the directional selection lever to the LOCK position CAUTION The shield should not electrically contact the cryostat Plastic sheeting...

Page 17: ...should be present to assist 1 With the ICS Stand fully lowered carefully roll the ICS assembly to the front of the lead shield 2 Carefully lift and tilt the ICS stand and ICS detector towards off the...

Page 18: ...the detector capsule with the center of the access hole in the shield bottom 6 Once centered attach the pneumatic air pump move the directional selection lever on the front of the ICS Stand to the UP...

Page 19: ...per position is reached Disconnect the pneumatic air pump and move the directional selection lever to the LOCK position CAUTION The shield should not electrically contact the cryostat Plastic sheeting...

Page 20: ...ND 2 IN POSITION This is done after the ICS is installed on the stand and the ICS Stand II is in its desired location in the shield Using the hex wrench provided torque the lock nut to a maximum of 13...

Reviews: