For the basic EC20S configuration, a few recommendations:
-
refer to 7.2 regarding the DC power supply,
-
refer to 9.1 regarding the multi-GNSS synchronization source,
-
refer to 9.2 and 9.3 regarding the External 1PPS/NMEA synchronization source.
6.5
START-UP SEQUENCE
For a standard configuration implementing the multi-GNSS synchronization source, after the system
initialization sequence, the GNSS receiver locks to the satellites constellations (event reported by the
‘
SRC
’ LED which switches from red to green),
and once the internal oscillator warming up is complete,
the oscillator is disciplined to get the
‘
Locked
’
conditions
(see 10.2). The whole process may take about
15 minutes.