Orno OR-PL-6092WLPMR4 Operating Instruction Download Page 4

 

(EN) Operation Instruction 

TECHNICAL SPECIFICATION

 

 

Rated 

Load 

luminous 

flux 

color 

temperatur

Light 
color 

CRI 

(Ra) 

Impact 

protection 

Size: 

Net weight 

Power 

sourcing 

Working temperature 

OR-PL-6092WLPM4 

12W 

850lm 

4000K 

neutral 

white 

>80 

IP20 

250 x 260 x 

60mm 

0,42 kg 

230V~, 50Hz 

-20

0

C~40

0

OR-PL-6105WLPMR4 

16W 

1150lm 

0,48 kg 

                                                                                                                       

light source:  

                                                                                                                     detection range: 
                                                                                                                          ambient light: 
                                                                                                                    time delay: min. : 
                                                                                                   adjustable daylight sensor: 

                                                                                                                detection distance: 

                                                                                                                     Lifetime LED: 

Impact protection:

  

5730 SMD 

360° (

ceiling mounting) 

<3-2000 lux 

10sek.±3sek.; max.3min±30sek.

 

ceiling 

(max. Ø6m)

 

2,2 m do 4 m 
50 000h 
IK07 

FUNCTION

 

Can identify day and night: The consumer can adjust working state in different ambient light. It can work in the daytime and  at night when it is 

adjusted on the “sun” position (max). It can work in the ambient light less than 3LUX when it is adjusted on the “moon” position (min). As for the 

adjustment pattern, please refer to the testing pattern.  
Time-Delay is added continually: When it receives the second induction signals within the first induction, it will restart to time from the moment. 
Adjustable Tim

e Delay: the length of time delay could be set according to the customers’ requirement, the minimum time of this item is 10sec±3sec, 

and the maximum is 

3min±30sec.

 

DESCRIPTION 

When choosing a mounting location, the following criteria should be taken into account: 
- the lamp should be installed on a ceiling 2.2-4m high or on a wall 1.8-2.5m high, 
- avoid installing close to heaters, fans or other devices which can cause sudden temperature change,  
- avoid installing in places where sun rays are directly aimed at the motion sensor, 
- do not place the lamp near objects that can be moved by strong wind (curtains or trees or bushes, etc.), 
- make sure that the power cables have adequate current protection in form of appropriate fuses or other devices disconnecting power in the 
event of overload, 
- if there is a slight difference in temperature of the moving object and the ambient temperature (i.e. in summer), the sensor can react later and the 
detection range will be reduced, 
- do not mount near sources of strong electromagnetic interference, 
- contamination of the sensor optics reduces the range and sensitivity of motion detection. 
The device should be installed by an authorized electrician. 
Do not install the lamp on uneven surfaces. 
Do not place any object

s that could disrupt sensor’s operation in front of the device.

 

Do not open the luminaire once the power has been connected. 

INSTALLATION

 

- Switch off the power. 
- Unscrew the plastic screw nut and remove the PC lampshade.(refer to figure1) 
- Pass the wire through the hole in the bottom and connect the power wire into connection-wire column according to the connection-wire 
diagram. Install the sensor lamp in the position where you need with inflated screws. (refer to figure2) 
- Switch on the power and test it 

 
 

 
 
 
 
 
 
 
 
Figure.1a 

 
 
 
 
 
 
 
 
 
 
 
Figure.1b

 

 
 
 
 
 
 
 
 
 
 
 
Figure.2 

 

 
 
 
 
                                             
 
 
 
 
 
 
 
 
Figure.3

 

SENSOR INFORMATION 

Figure.4a  

 
 
 
 
 
 
 
 
 
 
 
 
Figure.4b  

Height of installation: 2.2-4m 

Detection Distance: Max.6m 

 

 

 

Summary of Contents for OR-PL-6092WLPMR4

Page 1: ...nrichtung nie ab 5 Bedienen Sie die Einrichtung nicht wenn das Geh use besch digt ist 6 ffnen Sie die Einrichtung nicht und f hren Sie keine selbstst ndigen Reparaturen aus 7 Verwenden Sie die Einrich...

Page 2: ...w pobli u grzejnik w wentylator w i innych obiekt w gdzie mog pojawia si gwa towne zmiany temperatury nie zaleca si monta u w miejscach gdzie promienie s oneczne mog pada bezpo rednio na czujnik ruchu...

Page 3: ...uchu wskaz wek zegara na minimum ksi yc je li nat enie wiat a otoczenia jest wi ksze ni 3 LUX czujnik przestanie dzia a i o wietlenie r wnie Je li nat enie wiat a otoczenia jest mniejsze ni 3 LUX ciem...

Page 4: ...2 2 4m high or on a wall 1 8 2 5m high avoid installing close to heaters fans or other devices which can cause sudden temperature change avoid installing in places where sun rays are directly aimed a...

Page 5: ...nt light The sensitivity is poor a Please check if there has any hindrance in front of the detection window to affect to receive the signal b Please check if the ambient temperature is too high c Plea...

Page 6: ...nge oder b ume oder b sche etc stellen sie sicher dass die stromleitungen ber einen ausreichenden stromschutz in form von geeigneten sicherungen oder anderen vorrichtungen verf gen die im falle einer...

Page 7: ...eingestellt Bei h herer Lichtintensit t wird der Strom f r ca 5 15 Sekunden ausgeschaltet Bei der Pr fung des Tageslichtsensors sollte der LUX Knopf auf MAX gestellt sein da der Sensor sonst nicht or...