5
INSTALLATION
1. Please move the upper cover with anti-clockwise whirl as per the diagram on the right.
2. Connect the power and the load according to the connection-wire diagram.
3. Fix the bottom on the selected position with the inflated screw.
4. Install back the upper cover on the sensor, then you could switch on the power and test it.
Figure 4
OPERATION - TEST OF THE APPLIANCE
-Turn the TIME knob anti-clockwise on the minimum (-). Turn the LUX
knob clockwise on the maximum (sun).
-Switch on the power; the sensor and its connected lamp will have no signal
at the beginning. After Warm-up 30sec, the sensor can start work .If the
sensor receives the induction signal, the lamp will turn on. While there is no
another induction signal any more, the load should stop working within
10sec±3sec and the lamp would turn off.
-Turn LUX knob anti-clockwise on the minimum. If the ambient light is
more than 3LUX, the sensor would not work and the lamp stop working
too. If the ambient light is less than 3LUX (darkness), the sensor would
work. Under no induction signal condition, the sensor should stop working
within 10sec±3sec.
LUX
- luminous intensity adjustment
This setting specifies the luminous intensity at which the device stops
motion detection while remaining in the stand-by mode. This secures
against undesirable lighting switching on by day. The lighting time is set
using the knob “LUX” that should be turned home clockwise; then wait for
dusk. When it darkens, set the lighting time by turning the knob “LUX” until
the light is turned on.
TIME
- the lighting time adjustment
The knob allows to specify the time of the device operation after the
sensor activation. The lighting time is counted from the motion detection
moment until switching off.
Figure 5
Note: when testing in daylight, please turn LUX knob to (SUN) position, otherwise the sensor lamp could not work! If the lamp is more than
60W, the distance between lamp and sensor should be 60cm at least.
REMARKS:
- Assembly and installation may be carried out by an electrician or an experienced person
- Do not use unstable objects as the installation base.
- Do not place any object in front of the appliance to avoid disturbance of the sensor operation.
- Do not install the sensor in the area of variable temperature, eg. in the vicinity of the air stream from the air conditioning, heat sources from the central heating, etc.
- Do not open the housing after the appliance is connected to the power supply.
SOME PROBLEM AND SOLVED WAY
The load does not work:
a. Please check if the connection of power source and load is correct.
b. Please check if the load is good.
c. Please check if the settings of working light correspond to ambient light.
The sensitivity is poor:
a. Please check if there is any hindrance in front of the detector to affect it to receive the signals.
b. Please check if the ambient temperature is too high.
c. Please check if the induction signal source is in the detection field.
d. Please check if the installation height corresponds to the height required in the instruction.
e. Please check if the moving orientation is correct.
The sensor can not shut off the load automatically:
a. Please check if there is continual signal in the detection field.
b. Please check if the time delay is set to the maximum position
SAFETY and MAINTENANCE
Maintenance should be carried out with power disconnected.
Clean only with delicate and dry fabrics.
Do not use chemical cleaners.
Do not cover the product.