Orno OR-CR-263 Operating Instruction Download Page 5

 

INSTALLATION 

  

1. Please move the upper cover with anti-clockwise whirl as per the diagram on the right. 

2. Connect the power and the load according to the connection-wire diagram. 

3. Fix the bottom on the selected position with the inflated screw. 

4. Install back the upper cover on the sensor, then you could switch on the power and test it. 

 
 
 
 
                                                                                                                                                                 Figure 4 

 

OPERATION - TEST OF THE APPLIANCE

 

-Turn  the  TIME  knob  anti-clockwise  on  the  minimum  (-).  Turn  the  LUX 
knob clockwise on the maximum (sun). 
-Switch on the power; the sensor and its connected lamp will have no signal 
at the beginning. After Warm-up 30sec, the sensor can start work .If the 
sensor receives the induction signal, the lamp will turn on. While there is no 
another  induction  signal  any  more,  the  load  should  stop  working  within 
10sec±3sec and the lamp would turn off.  
 
-Turn  LUX  knob  anti-clockwise  on  the  minimum.  If  the  ambient  light  is 
more than 3LUX, the sensor would not work and the lamp stop working 
too. If the ambient light is less than 3LUX (darkness), the sensor would 
work. Under no induction signal condition, the sensor should stop working 
within 10sec±3sec. 

 

LUX 

- luminous intensity adjustment 

This setting specifies the luminous intensity at which the device stops 
motion detection while remaining in the stand-by mode. This secures 
against undesirable lighting switching on by day. The lighting time is set 
using the knob “LUX” that should be turned home clockwise; then wait for 
dusk. When it darkens, set the lighting time by turning the knob “LUX” until 
the light is turned on. 

TIME

 - the lighting time adjustment 

The knob allows to specify the time of the device operation after the 
sensor activation. The lighting time is counted from the motion detection 
moment until switching off. 

 
 
 
 
 
   Figure 5

 

 

Note: when testing in daylight, please turn LUX knob to          (SUN) position, otherwise the sensor lamp could not work! If the lamp is more than 
60W, the distance between lamp and sensor should be 60cm at least. 

REMARKS:

 

- Assembly and installation may be carried out by an electrician or an experienced person  
- Do not use unstable objects as the installation base.  
- Do not place any object in front of the appliance to avoid disturbance of the sensor operation. 
- Do not install the sensor in the area of variable temperature, eg. in the vicinity of the air stream from the air conditioning, heat sources from the central heating, etc. 
- Do not open the housing after the appliance is connected to the power supply.

  

 

 

 

 

 

SOME PROBLEM AND SOLVED WAY

 

The load does not work: 

a. Please check if the connection of power source and load is correct. 
b. Please check if the load is good. 
c. Please check if the settings of working light correspond to ambient light. 

The sensitivity is poor: 

a. Please check if there is any hindrance in front of the detector to affect it to receive the signals. 
b. Please check if the ambient temperature is too high. 
c. Please check if the induction signal source is in the detection field. 
d. Please check if the installation height corresponds to the height required in the instruction. 
e. Please check if the moving orientation is correct. 

The sensor can not shut off the load automatically: 

a. Please check if there is continual signal in the detection field. 
b. Please check if the time delay is set to the maximum position 

SAFETY and MAINTENANCE

 

Maintenance should be carried out with power disconnected. 
Clean only with delicate and dry fabrics. 
Do not use chemical cleaners. 
Do not cover the product. 
 

Summary of Contents for OR-CR-263

Page 1: ...rameter und Nutzwerte des Produkts nicht beeintr chtigen Die neuste Version der Bedienungsanleitung ist verf gbar zum Download unter www orno pl Alle Rechte auf bersetzung Auslegung sowie Urheberrecht...

Page 2: ...o e by wykryty ruch zwierz t czujnik nie powinien by kierowany na o wietlane jasne obiekty tj bia e lub b d ce r d em ciep a poniewa mog one wp ywa negatywnie na prac czujnika nie montowa w pobli u si...

Page 3: ...przekr ci do oporu zgodnie z ruchem wskaz wek zegara i poczeka do zmierzchu Gdy zacznie si ciemnia nale y ustawi por wiecenia przekr caj c pokr t o LUX do momentu w czenia si wiat a TIME regulacja cza...

Page 4: ...the maximum is 7 min 2 min high sensitivity low sensitivity Figure 1 While choosing a place of installation consider the following criteria detection angle of the sensor the sensor should not be aimed...

Page 5: ...tion after the sensor activation The lighting time is counted from the motion detection moment until switching off Figure 5 Note when testing in daylight please turn LUX knob to SUN position otherwise...

Page 6: ...min 2 min Gute Empfindlichkeit Geringe Empfindlichkeit Abb 1 Bei der Auswahl des Montageortes sind die folgenden Kriterien zu ber cksichtigen Winkel der Reichweite des Sensors der Sensor sollte nicht...

Page 7: ...der Umgebung gr er als 3 Lux werden der Sensor und die Beleuchtung aus Betrieb gesetzt Ist die Lichtst rke der Umgebung kleiner als 3 Lux Dunkelheit schalten der Sensor wieder ein Gibt es kein Signal...

Reviews: