Electrical rating

115 V/230 V~
50/60 Hz
15 V/ 27 VA

Input current

0.3 Amps

Rated

1.33 A

Transformer

Safety transformer 
EN 60742

Protection class

II

Length

45.27 inches/115 cm

Width

15.5 inches/ 39.5 cm

Height

21.7 inches /55 cm

Length adjustment 
for lower leg

15.5 inches/ 39.5 cm
- 22 inches /56 cm

Length adjustment 
for upper leg

12.5 inches /32 cm

(approximate length)

-19.7 inches / 50 cm

Weigth

26 lb. /13 kg

Materials used

Steel: 1.4301;
1.4305; 1.4310
Aluminium: AlMg3;
AlCuMgPb F38,
Brass
Synthetic material:
PA6.6; Polystyrol
PVC; PE 1000;
FR4 Electronic
board;
Polyurethane;
rubber
Support: synthetic
fleece (Polyester)

Technical data subject to change

MPG:

Class 2a

Power supply

NTEV20
Safety Transformer
In: 115 /230 V ~
50/60 HZ, 27 VA
Out: 15 V ~ 1.33 A
Manufacturer:
Ulmer

– Always unplug the device before

cleaning

– The ARTROMOT

®

-K4 can be wiped

clean with desinfectant and therefore
complies with the required standards
of hygiene for medical equipment.

– The housing can be cleaned using

commonly available disinfectants and
mild household detergents.

– The device itself should only be wiped

down with damp cloth.

– The plastics used are not resistant 

to mineral acids, formic acid, phenol,
cresol, oxidising or strong organic 
and inorganic acids with a pH value 
of less than 4.

– Protect the device from intensive

ultraviolet radiation (sunlight).

Surrounding Conditions

Surrounding 
temperature

-11

O

F to +140

O

F

Relative humidity 20 % to 85 %
Air pressure

700 hPa to 1060 hPa

Operational Conditions

Surrounding 
temperature

+ 50

F to + 104

O

F

Relative humidity 30 % to 75 %
Air pressure

700 hPa to 1060 hPa

13

12

6. Maintenance

7. Specifications

PRECAUTION!

Never allow liquids to get inside
the housing or hand-held pro-
gramming unit.

If you have any questions regarding
product or service, please do not 
hesitate to contact us:

ORMED international
Please contact your local dealer or

Headquarters Germany
ORMED GmbH & Co. KG
Merzhauser Straße 112
D-79100 Freiburg, Germany

Tel. +49-(0)-761-4566-281
Fax +49-(0)-761-4566-55 281
e-mail: [email protected]

USA, St. Paul
Tel. 1-800-440-2784
Fax 1-651-415-7414
e-mail: [email protected]

Czech Republic, Prague
Tel. 02-84094650
Fax 02-84094660
e-mail: [email protected]

Internet:
www.ormed.de
e-mail: [email protected]

www.ormedusa.com

Technical hotline:

Do you have any technical questions?
Do you need Technical service?

Tel. +49-180-5-1-ormed.de

+49-180-5-1-676 333

Fax +49-180-5-3-ormed.de

+49-180-5-3-676 333

To avoid transport damages, use only
the original packing boxes. These
boxes can be ordered from Ormed.
Before carrying the device, always
make sure the femur length adjustment
is locked.

Maintenance:
Not necessary

Guarantee:
2 years warranty on mechanical and
electronical parts

Manufacturer:
ORMED GmbH & Co. KG
Merzhauser Straße 112
D-79100 Freiburg

8. Service

PRECAUTION!

Carry out regular checks at short
intervals for possible damage and
loose connections. Damaged or
worn parts should be replaced
immediately with original spare
parts by an authorized specialist.

Summary of Contents for ARTROMOT-K4

Page 1: ...Operation Manual ARTROMOT K4...

Page 2: ...2 12 13 17 11 10 9 14 8 1 2 5 15 16 3 4 7 6 18 19 19 20 21 22 23 3 Device description Figures Fig 2 Fig 3 Fig 4 Fig 5 Fig 6 Fig 7 Fig 8...

Page 3: ...hroscopy procedures in combination with synovectomy arthrolysis or other intra articular measures mobilsations of joints in narcosis operative treatments on fractures pseudarthrosis and inversion oper...

Page 4: ...persons as otherwise all warranty services and liabilities shall be void Perform regular checks on all compo nents for possible damage or loose connections Damaged or worn parts should be replaced im...

Page 5: ...OMOT K4 features a true anatomical knee and hip axis for maximum patient comfort ARTROMOT K4 has to be set up either for the right or left leg The device can be converted quickly The procedure is easi...

Page 6: ...Speed Minimum setting for speed 1 Maximum setting for speed 100 Special functions are Center warm up Full speed motion double speed setting Runtime patient runtime Device runtime Programming the spec...

Page 7: ...lative humidity 20 to 85 Air pressure 700 hPa to 1060 hPa Operational Conditions Surrounding temperature 50O F to 104O F Relative humidity 30 to 75 Air pressure 700 hPa to 1060 hPa 13 12 6 Maintenance...

Page 8: ...dical Devices Part 1 and 2 additional norm electromagnetic compatibility requirements and testing The adherence to the standard specifications entitles to marking of these devices with CE 0297 0297 Fr...

Reviews: