38
39
12.2.3 Settings
Function
Description
Comfortable temp.
Desired temperature of hot water during heating.
Programme
Set the mode a circuit:
a. time - according to preset ranges
b. constant - regardless of the time intervals comfortable
temperature is maintained
c. disabled - off the heat.
Heat now
Heats hot water once to a comfortable temperature
regardless of the program.
Hysteresis
The value of which can reduce the temperature of hot
water.
Economical temp.
Desired temperature of hot water outside the period of
heating.
12.2.4 Time program
Used to configure the time steering hot water preparation.
Description of the adjustment time refer to chapter 10.4.
12.2.5 Service
WARNING!
Access the service is intended only for qualified technical personnel. The changes may
cause malfunction of the system.
Function
Description
Source delta
Increasing the temperature of the source of the desired
temperature of hot water during heating.
Source
Specifies the source of energy for hot water.
Temperature MAX
Maximum temperature of hot water.
Delta MIN temp.
The minimum temperature difference between the source
and the hot water at which the pump can work.
Pump test
Starts the pump regardless of other conditions.
Circ. name
Gives name for the hot water circuit.
Summary of Contents for ORLIGNO 100 16kW
Page 1: ...ORLIGNO 100 16 24 49 kW MANUAL AND SERVICE MANUAL ISO 9001 ISO 14001 ...
Page 7: ...1 5 Boiler dimensions 16kW 7 24kW 49kW ...
Page 10: ...16kW 24kW 10 ...
Page 17: ...17 Pic 5 Burner assembly Pic 6 Feeder assembly 4 1 5 3 2 6 7 10 9 9 8 11 12 ...
Page 34: ...12 Main menu 41 44 46 47 48 50 52 58 59 34 ...
Page 55: ...55 ...