8
SM0974023 A 01
System manual
LineMax 300 (03272525)
Max. range
300m*
TDV90 (8930061)
RDV90 (8930141)
Transmitter
Receiver
Spectrum Scanner set:
RDV90
* environment dependant
TDV90
Figure 9
Figure 10
7.1. Connecting Spectrum Scanner receiver
Connect the monitor cable to the 7p connection on the Spectrum Scanner
receiver. See figure 9.
Power
18-30V/DC
to power supply
Receiver
7p
2
5
7
4
3
6
1
Solderside 8p connectors:
Solderside 7p connectors:
Transmitter
Receiver
To Camera
Power input
(see specs)
To Display
7p female
8p female
7p male
Units in mm
62,2
98,2
132,8
6
7
1
3
4
5
2
8
1 = Red (power input see specs) 5 = White/Yellow (GPI 3)
2 = White (0V)
6 = Grey (GPO 1)
3 = Blue (GPI 1)
7 = Yellow (GPO 2)
4 = Brown (GPI 2)
8 = N.C. (GPO 3)
1 = Coax core (video)
5 = Orange (RX)
2 = Coax shielding (video GND) 6 = Yellow (TX)
3 = Red (12-30V/DC)
7 = Grey
4 = Black (0V)
30
M6 (4x)
depth=6
40,5