6
IM0973171 A 01
Installation Manual
8. Maintenance and cleaning.
Use a soft cloth to remove dirt etc. from the lens.
Do
not
clean this product with aggressive chemicals
or abrasive cleaning agents.
The filling valve may
ONLY
be used by the manufacturer.
Do not remove the blue seal.
See figure 9.
The warranty expires when
the blue seal is broken!
The warranty expires when the user does not act
according the instructions and warnings in this
manual.
9. Product specifications
Camera PT TIC
PAL/NTSC
SSt 0506982;
Camera PT TIC
PAL/NTSC
Alu 0506972
9.1. Thermal Image Camera
Sensor
: Uncooled LWIR Thermal Imager 336 x 256 VOx Microbolo-
meter.
Pixel size
: 25 micron.
Frame Rates
: 30/60 Hz (NTSC); 25/50 Hz (PAL).
Sensitivity
: <50 mk f/1,0.
Scene Range
: High Gain -40°C to +160°C. Low Gain -40°C to
+550°C.
Digital zoom
: 2x & 4x.
Video
: NTSC/PAL, field switchable.
Lens:
WFOV (Wide Field Of View), 19mm (f1.24) 24° x18°.
Color
: 15 Color Palettes (LUTs).
Power consumption
: Camera unit; Temperature <0°C (heater on):
5,6W, Temperature >0°C (heater off): 3,6 W.
9.2. Pan & Tilt
Pan angle:
Total 360°, 180° left, 180° right.
Tilt angle:
Total 180°, 90° up, 90° down.
Backlash Pan & Tilt:
1°.
Presets:
128 presets Visca and 255 presets Pelco-D.
Controls:
The PT TIC camera can be controlled by means of the
Monitor 7” RLED Serial; article no. 0208231 or the Monitor 10” Se-
rial art. no. 0206530.
Pan & Tilt speed:
12,5°/sec.
Power consumption:
Pan & Tilt; 24V, 12W.
9.3. General
Housing Sst:
stainless steel 316
Housing Alu
: anodised aluminium housing corrosion proof accord-
ing IEC 60068-2-52 salt mist, cyclic.
Weight Sst:
16 kg, including 3,5 metre cable for installation (total
5m).
Weight Alu:
5kg, including 3,5 metre cable for installation (total 5m).
Protection:
IP 69K according IEC 60529, 1,4 Bar overpressure filled
with dry nitrogen.
Operating temp:
-40°C to +85°C.
Communication
: Communication via serial interface, Visca-, Pelco-D
protocol (RS232) 9,6 Kbps.
Fall protection:
Steel cable, 2mm, including Steel cable U clamps.
Figure 9
Filling valve
Filling valve