IM0973171 A 01
11
16. Disposal
Disassembly, removal and disposal. Local regulations for dealing with
waste must be followed when disposing of disassembled components or
entire units.
17. General terms and conditions
Orlaco Products BV is not liable for damage resulting from inadequate
servicing, incorrect usage or alterations made to the equipment without
informing the manufacturer in writing.
This installation manual has been made available by Orlaco Products
BV. All rights reserved. No part of this manual may be reproduced and/
or made public in printed form, in photocopy form or on microfilm, or in
any other way, without the prior written permission of Orlaco. This also
applies to the associated drawings and figures.
Orlaco reserves the right to make changes to components at any time
without informing customers beforehand or directly. All dimensions given
are for commercial purposes.
For information regarding repairs that is not covered in this manual,
please contact the Orlaco Products BV service department.
This manual has been prepared with all due care and attention. However,
Orlaco Products BV cannot be held responsible for any errors in this
manual or any consequences thereof.
FCC compliance statement:
The camera comes under section for commodity codes for electronic
equipment. This is known as “Harmonize code: 8525.30.9060” and the
importer can check off Block 2 on FCC form which states: “An FCC grant
of equipment authorization and an FCC ID are not required, but the equip-
ment complies with FCC technical requirements.”
Caution:
Any changes or modifications in the construction of this device
which are not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment. Camera/Monitor
sets are visual aids and objects visible in camera/Monitor systems are
smaller or bigger than they appear on screen.
18. Release Notes
R1-0
First Edition.
R1-1
Specifications; page 7: Scene range improved. Jan 2013.
R1-2
Text Chapter 1, page 3 changed, 5/2013.
R1-3
Fuses deleted, page 5; Oct 2013
R1-4
Wire rope clamp installation added, page 4, 7/2014.
R1-5
Chapter 8 Specs changed, 7/2014.
R1-6
Stainless steel version added, manual IM0973170 is expired,
10/2014.
R1-7
RS485 PTTIC cameras added, January 2015.
R1-8
Mounting safety cables added and
panning PTTIC changed from
340
°
to 360
°
, January 2015.
R1-9
Chapter 9; specifications changed, January 2016.
A 01
RS485 deleted, Art. No Cameras changed, September 2017.
15. Additional TIC camera serial commands
TIC camera will also handle the zoom in, zoom out and pan/tilt move
commands (when zoomed in).
TIC settings command:
<0x80 + address> <V_COMMAND> <V_CATEGORY_CAMERA1> <V_
ORLACO_EXTENSION> <V_ORLACO_SET_SYSPROP> <0x00> <0x00>
<0x00> <IDH> <IDL> <VALH> <VALL> <V_TERMINATOR>
TIC settings:
Color Lookup Table (0x1B):
White hot
- IDH=0x01, IDL=0x0B, VALH=0x00, VALL=0x00
Black hot
- IDH=0x01, IDL=0x0B, VALH=0x00, VALL=0x01
Fusion
- IDH=0x01, IDL=0x0B, VALH=0x00, VALL=0x02
Rainbow
- IDH=0x01, IDL=0x0B, VALH=0x00, VALL=0x03
Ice&Fire
- IDH=0x01, IDL=0x0B, VALH=0x00, VALL=0x04
Digital Detail Enhancement (0x1C):
DDE off
- IDH=0x01, IDL=0x0C, VALH=0x00, VALL=0x00
DDE low
- IDH=0x01, IDL=0x0C, VALH=0x00, VALL=0x01
DDE medium
- IDH=0x01, IDL=0x0C, VALH=0x00, VALL=0x02
DDE high
- IDH=0x01, IDL=0x0C, VALH=0x00, VALL=0x03
Spot meter (0x1D):
Spot meter off
- IDH=0x01, IDL=0x0D, VALH=0x00, VALL=0x00
Spot meter bar °C
- IDH=0x01, IDL=0x0D, VALH=0x00, VALL=0x01
Spot meter bar F
- IDH=0x01, IDL=0x0D, VALH=0x00, VALL=0x02
Spot meter number °C - IDH=0x01, IDL=0x0D, VALH=0x00, VALL=0x03
Spot meter number F - IDH=0x01, IDL=0x0D, VALH=0x00, VALL=0x04
Spot meter bar + number °C - IDH=0x01, IDL=0x0D, VALH=0x00, VALL=0x05
Spot meter bar + number F - IDH=0x01, IDL=0x0D, VALH=0x00, VALL=0x06
Video standard (0x1E):
PAL
- IDH=0x01, IDL=0x0E, VALH=0x00, VALL=0x00
NTSC
- IDH=0x01, IDL=0x0E, VALH=0x00, VALL=0x01
Video Orientation (0x1F):
normal
- IDH=0x01, IDL=0x0F, VALH=0x00, VALL=0x00
flip
- IDH=0x01, IDL=0x0F, VALH=0x00, VALL=0x01
mirror
- IDH=0x01, IDL=0x0F, VALH=0x00, VALL=0x02
flip
- IDH=0x01, IDL=0x0F, VALH=0x00, VALL=0x03
Flat Field Correction (0x20):
Do FFC
- IDH=0x02, IDL=0x00, VALH=0x00, VALL=0x01