ORIUM Quaelis 14 User Manual Download Page 1

Imported by : 

AIC International - 44980 Ste Luce sur Loire - France 

 

CO2 AIR QUALITY MONITOR 

 

User's manual 

 

Please read the product instructions carefully before use. Please keep this leaflet in a safe place. 

 

The Quaelis 14 CO2 meter (part number 11325) has been designed for indoor use only. 

 

Carbon dioxide is an odourless and colourless gas from various sources (greenhouse gases, transport, fuel oil, heating, 
etc.).  

 

Carbon dioxide (CO2), which occurs naturally in the atmosphere, is a molecule produced by the human body during 
respiration.  Its  concentration  in the  indoor  air  of  buildings  is  related  to  human  occupancy  and  air  change,  and  is  an 
indicator of the level of air confinement. For this reason, the concentration of CO2 in indoor air is one of the criteria on 
which the regulation of ventilation in buildings is based. Current regulatory or normative limit values usually vary between 
1000 and 1500 ppm. They apply to school buildings, residential buildings and offices and have no significance for the 
health quality of indoor air. 

 

Source : www.anses.fr 

 

The  Quaelis  14  carbon  dioxide  (CO2)  meter  allows  continuous  measurement  of  the  CO2  level  and 
provides a practical, timely and alternative prevention solution to the decree (referred to in Article 5.1 of 
Decree  No.  2015-1000  of  17  August  2015:  2012-14  on  the  measurement  of  indoor  air  pollutants  in 
establishments open to the public (ERP). 

 

Art. 5 - 1. - The pollutant campaign consists of a continuous measurement of carbon dioxide (CO2) carried out over a 
single period, during the facility's heating period, if any. 

 

The Quaelis 14 CO2 meter has been designed to continuously monitor and analyse the CO2 (carbon 
dioxide) concentration level as well as the temperature and humidity of the room in real time. 

 

Technical characteristics : 

 

Colour LCD screen. 

CO2 measurement. Technology: NDIR sensor. 

Display of time, temperature and indoor humidity. 

Adjustable brightness. 

A wake-up alarm 

Power supply: 500 mAh rechargeable battery via DC 5.0V USB adapter cable (supplied). 

 
 

Measuring range 

CO2 

From 400 to 5000 ppm 

Temperature 

From -9°c to +50°C 

Moisture content 

From 1% to 99%. 

Accuracy 

CO2 

50 ppm +/- 5%. 

Temperature 

+/- 1% 

Moisture content 

+/- 2% 

Sensitivity/ resolution 

CO2 

1 ppm 

Temperature 

1°C 

Moisture content 

1% 

 

Take the product out of its packaging and check that all parts are included. 

 

Transport  and  protective  packaging  of  the  product  requires  the  meter  to  be  placed  in  a  well-
ventilated area for 30 minutes before use to allow the sensors to clear. 

 
 
 
 
 
 
 
 
 
 
 
 

 

Reviews: