LED
AREA LIGHTER
INSTALLATION INSTRUCTIONS
PRODUCT
SERIES: ARXS1
Ambient temperature for lighting fixture: -30
℃
~50
℃
Safety Instruction
¾
Read instructions carefully before attempting to install fixture. Retain instruction for future reference.
¾
All wiring should be performed by a qualified electrician.
¾
Disconnect power before installing or servicing. This fixture must be wired in accordance with the National Electrical
Code and applicable local codes and ordinances.
¾
Proper grounding is required to ensure personal safety.
¾
This fixture is for outdoor use and should not be used in areas with limited ventilation or high ambient temperatures.
¾
Caution
– Risk of Fire
WARNING: Make certain power is OFF before installing or maintaining fixture. No user serviceable parts
inside.
Location
Fixture should be located at least 18” below any overhang or other structural detail.
Fixture should not be recessed.
Installation
This flood light is supplied with trunnion mounting
This flood light is also available with anadjustable
bracket for surface mounting, make sure fixture is
Slip Fitter.
securely mounted.
Trunnion:
Slip Fitter
The trunnion mounting bracket offers five
1. Assemble slip fitter and gasket to Housing using
different positions. There are three position
hardware provided
holes in the outer yoke and five positioning
2. Assemble lower fitter onto the upper fitter after
holes in the inner yoke. To make a selection,
removing splice compartment cover.
remove the positioning screw, loosen trunnion
3.Slip lower fitter over tenon and securely tighten
bolts, rotate trunnion to desired angle. Reinsert
two allen head set screws. The lower fitter is
positioning screw and tighten.
designed to slip over 2-3/8’’ o.d. heavy wall pipe
or tenon