AREA LIGHTER

 INSTALLATION INSTRUCTIONS

PRODUCT 

SERIES: ARXS1

 

Ambient temperature for lighting fixture: -30

~50

 

Safety Instruction   

¾

Read instructions carefully before attempting to install fixture. Retain instruction for future reference.

¾

All wiring should be performed by a qualified electrician.

¾

Disconnect power before installing or servicing. This fixture must be wired in accordance with the National Electrical

Code and applicable local codes and ordinances.

¾

Proper grounding is required to ensure personal safety.

¾

This fixture is for outdoor use and should not be used in areas with limited ventilation or high ambient temperatures.

¾

Caution

 – Risk of Fire

WARNING: Make certain power is OFF before installing or maintaining fixture. No user serviceable parts 
inside.  

Location 

Fixture should be located at least 18” below any overhang or other structural detail. 

Fixture should not be recessed. 

Installation  

This flood light is supplied with trunnion mounting   

  This flood light is also available with anadjustable 

bracket for surface mounting, make sure fixture is  

  Slip Fitter. 

securely mounted.   

Trunnion:

         

 

Slip Fitter

 

The trunnion mounting bracket offers five    

1. Assemble slip fitter and gasket to Housing using

different positions. There are three position   

hardware provided

holes in the outer yoke and five positioning       

2. Assemble lower fitter onto the upper fitter after

holes in the inner yoke. To make a selection,   

removing splice compartment cover.

remove the positioning screw, loosen trunnion     

3.Slip lower fitter over tenon and securely tighten

bolts, rotate trunnion to desired angle. Reinsert     

two allen head set screws. The lower fitter is

positioning screw and tighten.   

designed to slip over 2-3/8’’ o.d. heavy wall pipe

or tenon