- 9 -
Alarming Output
4.3.
This software provide 4 channel alarming output, and switch by click in page table.
PTZ Control
4.4.
Notice: PTZ control only effective for the device which own PTZ.
Preset Control
4.4.1.
Add preset: select [Setup] at pull-down menu of preset. Select setting position on PTZ direction key of the
PTZ page and click [Add].Select preset ID and give a name to this preset. Click [Save] and accomplish preset.
Call preset: Select preset name item [Name] in preview interface, click [Call] button and enable to call
preset.
Tour Control
4.4.2.
Add tour: Adjust PTZ controlling to ‘tour’, click [Setup] to enter into interface.
Tour is multi-presets tour function which based on multiple assured point. So please set up several presets
in advance.
Click [Add], enter tour ID and name, select preset which have been set up from pull-down menu. Add
preset as tour preset point, click [Save] after adding all presets that you need.
Scan Control
4.4.3.
Add scan: Select scan in PTZ setup interface, click [Setup] enter into scan configuration interface.
Scan function make device move over and over again between two points that have been setup within the
shortest time, which control local region with best efficiency.
Enter into scan interface, click [Add], then click [Start] at the start position, select [Stop] to confirm the end
points by PTZ direction key.
Notice: scan is linear motion in the shortest distance between start point and end point, will not record
any other points where it passed.
User can also adjust scan speed and scan direction in configuration interface.