background image

Q I G

Quick Installation Guide

Q

uick

I

nstallation

G

uide

Q I G

Specifications

Resetting

To restore the device configurations back to the factory defaults, press the

button for 5

Reset

seconds. Once the power indicator starts to flash, release the button. The device will then reboot
and  return  to  factory  defaults.

PRINTED  ON  RECYCLED  PAPER

ORing Industrial Networking Corp.

Copyright©  2021 ORing

All rights reserved.

TEL: +886-2-2218-1066
FAX: +886-2-2218-1014

Website: www.oringnet.com
E-mail: [email protected]

Configurations

6

5

7

3

2

1

8

4

After installing the

and connecting cables, he green power LED

switch

t

should turn on. Please refer to the following tablet for LED indication.

3. After logging in, you should see the following screen. For more information on
configurations, please refer to the user manual. For information on operating the device
using ORing’s Open-Vision management utility, please go to ORing website.

Version 1.0

10/100/1000Base-T(X) M12 port with X-Coding

Pin No.

Description

#1

BI_DA+

#2

BI_DA-

#3

BI_DB+

#4

BI_DB-

#5

BI_DD+

#6

BI_DD-

#7

BI_DC-

#8

BI_DC+

8-Pin Gigabit Port Definition

LED

Color

Status

Description

PWR1

Green

On

DC power module 1 activated

PWR2

Green

On

DC power module 2 activated

R.M

Green

On

Device operating in Ring Master mode

Ring

Green

On

Ring enabled

Blinking

Ring structure is broken

Fault

Amber

On

Errors occur (i.e. power failure or port malfunctioning)

10/100Base-T(X) Ethernet ports

LNK/ACT

Green

On

Port is linked

Blinking

Transmitting data

Speed

Amber

On

Port is running at 100Mbps

Off

Port is running at 10Mbps

10/100/1000Base-T(X) Ethernet ports

LNK/ACT

Green

On

Port is linked

Blinking

Transmitting data

Speed

Green

On

Port is running at 1000Mbps

Amber

On

Port is running at 100Mbps

Green/Amber

Off

Port is running at 10Mbps

1. Launch the Internet Explorer and type in IP address of the device. The default static
IP address is

192.168.10.1

Follow the steps below to log in and access the system:

2. Log in with default user name and password (both are

).

admin

Power

Input Power

Power Consumption(Typ.)

Dual 24VDC (power rating: 16.8~30VDC) on dual 4-pin male S-coding connector

20 Watts

Reset Function

Reset Button

< 5 sec: System reboot, > 5 sec: Factory default

Overload Current Protection

Reverse Polarity Protection

Present

Present

ORing Switch Model

10/100 Base-T(X) Ports in

M12 Auto MDI/MDIX

12 (4-pin female D-coding)

Physical Ports

Technology

Ethernet Standards

IEEE 802.3 for 10Base-T

IEEE 802.3u for 100Base-TX

IEEE 802.3ab for 1000Base-T

IEEE 802.3x for Flow control

IEEE 802.3ad for LACP (Link Aggregation Control Protocol)

IEEE 802.1p for COS (Class of Service)

IEEE 802.1Q for VLAN Tagging

IEEE 802.1w for RSTP (Rapid Spanning Tree Protocol)

IEEE 802.1s for MSTP (Multiple Spanning Tree Protocol)

IEEE 802.1x for Authentication

IEEE 802.1AB for LLDP (Link Layer Discovery Protocol)

8k

MAC Table

8

Priority Queues

TES-W9124GT-M12X-BP2-24V-IP54

10/100/1000Base-T(X) ports

in M12

4 (8-pin female X-coding with 2xbypass function included)

RS-232 Serial Console Port

RS-232 in M12 connector (female A-coding).  Baud rate setting: 115200bps, 8, N, 1

Store-and-Forward

Processing

Switch Properties

Switching latency: <7 µs

Switching bandwidth: 10.4Gbps

Throughput (packet per second): 7.738Mpps@64Bytes packet

Max. Number of Available VLANs: 4095

IGMP multicast groups: 128 for each VLAN

Port rate limiting: User Define

Security Features

Device Binding security feature

Enable/disable ports, MAC based port security

Port based network access control (802.1x)

VLAN (802.1Q) to segregate and secure network traffic

Radius centralized password management

SNMPv3 encrypted authentication and access security

Https / SSH enhance network security

Software Features

STP/RSTP/MSTP (IEEE 802.1D/w/s)

Redundant Ring (O-Ring) with recovery time less than 10/30ms over 250 units

. Fast Ethernet ports supports less 10ms milliseconds recovery time

NOTE 1

Gigabit Ethernet ports supports less 30ms milliseconds recovery time

NOTE 2.

TOS/Diffserv supported

Quality of Service (802.1p) for real-time traffic

VLAN (802.1Q) with VLAN tagging and GVRP supported

IGMP Snooping

IP-based bandwidth management

Application-based QoS management

DOS/DDOS auto prevention

Port configuration, status, statistics, monitoring, security

DHCP Server/Client/Relay

SMTP Client

Modbus TCP

Network Redundancy

O-Ring

O-Chain

MRP

*NOTE

MSTP (RSTP/STP compatible)

4Mbits

Packet Buffer Size

Up to 9.6K Bytes

Jumbo Frame

Physical Characteristic

Enclosure

IP-54

Dimension (W x D x H)

280 (W) x 90 (D) x 182 (H) mm (11.02 x 3.54 x 7.17 inch.)

Weight (g)

3215 g

Environmental

-40 to 85 C (-40 to 185 F)

o

o

Storage Temperature

5% to 95% Non-condensing

Operating Humidity

Regulatory Approvals

EN 55032, CISPR32, EN 61000-3-2, EN 61000-3-3, FCC Part 15 B class A

EMI

EN 55035 (IEC/EN 61000-4-2 (ESD), IEC/EN 61000-4-3 (RS), IEC/EN 61000-4-4 (EFT),

IEC/EN 61000-4-5 (Surge), IEC/EN 61000-4-6 (CS), IEC/EN 61000-4-8(PFMF), IEC/EN 61000-4-11 (DIP))

EMS

IEC60068-2-27

Shock

IEC60068-2-31

IEC60068-2-6

Vibration

Free Fall

MTBF

177,214 hrs

EN 62368-1 (LVD)

Safety

-40 to 75 C (-40 to 167 F)

o

o

Operating Temperature

*Note: This function is available by request only.

CE EMC (EN 55035, EN 55032), FCC Part 15 B, EN 50155(EN 50121-1, EN 50121-3-2)

EMC

EN 50155(IEC 61373)

Other

Warranty

5 years

TES-W9124GT-M12X-BP2-24V-IP54

TES-W9124GT-M12X-BP2

-24V-IP54

EN50155 Industrial IP-54 managed

Ethernet switch

S w i tc h

E N 5 0 1 5 5

I N D U S T R I A L

I P - 6 7

Reviews: