Shutdown
Specify the port shut down operation of this port. The allowed values
are:
Enabled: If a frame is received on the port, the port will be disabled.
Disabled: Port shut down is disabled.
The default value is "Disabled".
Counter
Counts the number of frames that match this ACE.
4.1.10.2 802.1x
This page allows you to configure how an administrator is authenticated when he logs into the
switchstack via TELNET, SSH or the web pages.