![ORiNG IPS-3082GC-AT User Manual Download Page 120](http://html1.mh-extra.com/html/oring/ips-3082gc-at/ips-3082gc-at_user-manual_1651972120.webp)
IPS-3082GC-AT
User’s Manual
ORing Industrial Networking Corp
Syslog server / client to record and view events
Include SMTP for event warning notification via email
Event selection support
DDM Function
Voltage / Current / Temperature
RS-232 Serial Console Port
RS-232 in RJ45 connector with console cable. 9600bps, 8, N, 1
LED indicators
Power/PoE Indicator
Green : Power LED x 3, Green : PoE LED x 8
O-Ring Indicator
Green : Indicate system operated in O-Ring mode
R.M. indicator
Green : Indicate system operated in O-Ring Master mode
Fault indicator
Amber : Indicate unexpected event occurred
10/100Base-T(X) RJ45 Port Indicator
Green for port Link/Act. Amber for Duplex/Collision
10/100/1000Base-T(X) RJ45 Port
Indicator
Green for Link/Act. Amber for 100Mbps indicator
100/1000Base-X Fiber Port Indicator
Green for port Link/Act.
Fault contact
Relay
Relay output to carry capacity of 1A at 24VDC
Power
Redundant Input Power
Dual DC inputs. 50 ~ 57VDC on 6-pin terminal block
Power Consumption (Typ.)
7.68 Watts (power consumption of P.S.E. is not included)
Overload Current Protection
Present
Reverse polarity protection
Not Presented
Physical Characteristic
Enclosure
IP-30
Dimension (W x D x H)
74.3 (W) x 109.2 (D) x 153.6 (H) mm (2.93 x 4.3 x 6.05 inch)
Weight (g)
1185 g
Environmental
Storage Temperature
-40 to 85
o
C (-40 to 185
o
F)
Operating Temperature
-40 to 75
o
C (-40 to 167
o
F)
Operating Humidity
5% to 95% Non-condensing
Regulatory approvals
EMI
FCC Part 15, CISPR (EN55022) class A
EMS
EN61000-4-2 (ESD), EN61000-4-3 (RS), EN61000-4-4 (EFT), EN61000-4-5 (Surge), EN61000-4-6 (CS),
EN61000-4-8, EN61000-4-11
Shock
IEC60068-2-27
Free Fall
IEC60068-2-32
Vibration
IEC60068-2-6
Safety
EN60950-1
Warranty