Q I G
Quick Installation Guide
PRINTED ON RECYCLED PAPER
Q
uick
I
nstallation
G
uide
Resetting
To reboot the switch, press the
button for 2-3 seconds.
To restore the switch configurations back to the factory defaults, press the
button for 5 seconds.
Reset
Reset
GIGABIT
I N D U S T R I A L
SWITCH
To connect the console port to an external management device, you need an RJ-45 to
DB-9 cable, which is also supplied in the package. Below is the console port pin
assignment information.
Console Port Pin Definition
PC (male) pin assignment
RS-232 with DB9 (female) pin
assignment (RJ45-DB9 cable)
RJ45 pin assignment
PIN#2 RxD
PIN#2 RxD
PIN#2 RxD
PIN#3 TxD
PIN#3 TxD
PIN#3 TxD
PIN#5 GND
PIN#5 GND
PIN#5 GND
Wiring
The switch supports dual redundant power supplies, Power Supply1
(PWR1) and Power Supply 2 (PWR2). The connections for PWR1,
PWR2 and the RELAY are located on the terminal block.
Insert the negative/positive wires into the V-/V+ terminals,
respectively.
To keep the DC wires from pulling loose, use a small flat-
blade screwdriver to tighten the wire-clamp screws on the front of the
terminal block connector.
STEP 1:
STEP 2:
PWR-1
PWR-2
1A@24V
V2- V2+
V1- V1+
Fault
Power inputs
The two sets of relay contacts of the 6-pin terminal block connector are used to detect user-
configured events. The two wires attached to the fault contacts form an open circuit when a
user-configured when an event is triggered. If a user-configured event does not occur, the
fault circuit remains closed.
Relay contact
Configurations
After installing the switch, the green power LED should turn on. Please refer to
the following tablet for LED indication.
1. Launch the Internet Explorer and type in IP address of the switch. The default static IP address is
192.168.10.1
2. Log in with default user name and password (both are
). After logging in, you should see
the following screen. For more information on configurations, please refer to the user manual. For
information on operating the switch using ORing’s Open-Vision management utility, please go to
ORing website.
admin
Follow the steps to set up the switch:
Power
Redundant Input power
Power consumption(Typ.)
Dual DC inputs. 12-48VDC on 6-pin terminal block
21 watts
Overload current protection
Present
Physical Characteristic
Enclosure
IP-30
Dimension (W x D x H)
200 (W) x 150 (D) x 150.8 (H) mm (7.87x5.9x5.9 inch)
RS-232 Serial Console Port
Switch Properties
Switch latency: 7 us
Switch bandwidth: 52Gbps
Max. Number of Available VLANs: 4095
VLAN ID Range :VID 1 to 4094
IGMP multicast groups: 128 for each VLAN
Port rate limiting: User Define
Security Features
Device Binding security feature
Enable/disable ports, MAC based port security
Port based network access control (802.1x)
Single 802.1x and Multiple 802.1x
MAC-based authentication
QoS assignment
Guest VLAN
MAC address limit
VLAN (802.1q) to segregate and secure network traffic
Radius centralized password management
SNMPv3 encrypted authentication and access security
Https / SSH enhance network security
Web and CLI authentication and authorization
IP source guard
Software Features
IEEE 1588v2 clock synchronization
IEEE 802.1D Bridge, auto MAC address learning/aging and MAC address (static)
Multiple Registration Protocol (MRP)
MSTP (RSTP/STP compatible)
Redundant Ring (O-Ring) with recovery time less than 30ms over 250 units
TOS/Diffserv supported
Quality of Service (802.1p) for real-time traffic
VLAN (802.1Q) with VLAN tagging and GVRP supported
IGMP Snooping for multicast filtering
IP-based bandwidth management
Application-based QoS management
Port configuration, status, statistics, monitoring, security
DHCP Server / Client support
DHCP Relay
SMTP Client
Modbus TCP
DNS client proxy
NTP server
Network Redundancy
O-Ring, O-chain, MRP, Fast Recovery, MSTP (RSTP/ STP compatible)
RS-232 in RJ45 connector with console cable. 115200bps, 8, N, 1 (support DBU-01 backup unit)
Weight (g)
3,042g(without module)
Jumbo frame
Up to 9.6K Bytes
Weight (g)
710 g
740 g
722 g
735 g
735 g
740 g
Environmental
-40 to 85 C (-40 to 185 F)
o
o
Storage Temperature
-40 to 75 C (-40 to 167 F)
o
o
Operating Temperature
5% to 95% Non-condensing
Operating Humidity
Regulatory Approvals
FCC Part 15, CISPR (EN55022) class A
EMI
EN61000-4-2 (ESD), EN61000-4-3 (RS), EN61000-4-4 (EFT), EN61000-4-5 (Surge),EN61000-4-6 (CS), EN61000-4-8, EN61000-4-11
EMS
EN50121-4(N50121-1)
Railway
Warranty
5 years
ORing Industrial Networking Corp.
Copyright© 2016 ORing
All rights reserved.
TEL: +886-2-2218-1066
FAX: +886-2-2218-1014
Website: www.oring-networking.com
E-mail: [email protected]
Specifications
ORing Switch Model
IGS-9122GPM
Physical Ports
Technology
Ethernet Standards
IEEE 802.3 for 10Base-T
IEEE 802.3u for 100Base-TX and 100Base-FX
IEEE 802.3z for 1000Base-X
IEEE 802.3ab for 1000Base-T
IEEE 802.3ad for LACP (Link Aggregation Control Protocol)
IEEE 802.3x for Flow control
IEEE 802.1D for STP (Spanning Tree Protocol)
IEEE 802.1p for COS (Class of service)
IEEE 802.1Q for VLAN Tagging
IEEE 802.1w for RSTP (Rapid Spanning Tree Protocol
IEEE 802.1s for MSTP (Multiple Spanning Tree Protocol)
IEEE 802.1x for Authentication
IEEE 802.1AB for LLDP (Link Layer Discovery Protocol)
10/100/1000Base-T(X) Ports
in RJ45 Auto MDI/MDIX
MAC Table
8K
Priority Queues
8
Processing
Store-and-Forward
12
100/1000Base-X with SFP port
2
Q I G
Version 1.0
Industrial Modular Managed Gigabit
Switch
LED
Color
Status
Description
PWR
Green
On
System power on
PW1
Green
On
Power module 1 activated
PW2
Green
On
Power module 2 activated
R.M
Green
On
System operated in O-Ring Master mode
On
System operated in O-Ring mode
Ring
Green
Blinking
Ring structure is broken
Fault
Amber
On
Errors occur (power failure or ports disconnected)
10/100/1000Base-T(X) Fast Ethernet ports
On
Port is Linked
LNK/ACT
Green
Blinking
Transmitting data
Green
On
Port in 1000Mbps speed
Amber
On
Port in 100Mbps speed
SPEED
(Dual color)
Green/Amber
Off
Port in 10Mbps speed
SFP ports
On
Port is linked
LNK/ACT
Green
Blinking
Transmitting data
Module Slot Number
2 (support 4x1G combo / 4x100Mbps Fiber module)
Fault Contact
Relay
Relay output to carry capacity of 1A at 24VDC
MTBF
540, 456 hrs
IGS-9122GPM
IGS-9122GPM